Previous Next
Sold on
2/7/13
Winning Bid
US $35,000
Won using Buy Now Price
# of Bids
1
SOLD!
ITEM DETAILS
Meter Reading
7,062 Hours
Serial #
40 Ton Capacity, 80' Foot Maximum Boom Length, 33' Foot Maximum Jib Length, Heater, Anti-Two-Block, Cummins V-555-C Engine, 3-Way Steering,***The state of Ohio does not require a title for this item. A Bill of Sale will be provided if requested.. Please check with your local agency for titling/export requirements***

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Safety Certification Label There is a safety certification label with a date of 12/23/12
Safety Certification Report None provided at time of inspection.
Load Chart Yes
CE Mark No
Paint Scratches; Chips; See photos for condition
Sheet Metal (fiberglass) Condition Minor dents; Surface rust in areas; See photos for condition
Steps/Ladders See photos for condition
Hand Rails See photos for condition
(8)


Control Station
Description Rating Details  
Seat Belts Operational
Mirrors No visible damage
Glass No visible damage
Seats/Armrests Torn cover
Horn Inoperable
Anti Two Block Operational
Hydraulic Controls
Drivetrain Controls
Oil Pressure The gauge registers in the operating range.; 25 PSI
Exterior Lights No
Gauges Operational; Inoperable air gauge
Hoist Brakes Hydraulic.
Hour Meter/Odometer (Start) 7061.8 Hours
Hour Meter/Odometer 7,062 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Indication of Additional Hours No other hrs were found on unit.
Heater Not operationally checked; Propane, fan did engage.
Limited Function Check The main components operated except as noted.
(22)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Certification Label None found
Blow by @ idle (subjective visual observation) Visible Click here to open photos and videos of this item.  
Starter Operational
Fuel System Operational
Exhaust System See photos for condition
Radiator
Oil Leaks See photos; Dripping Leak: Side of engine; Fluid Accumulation: Oil Pan
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check (Engine) The engine started and ran. See oil report.
(10)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational; Low oil level; Dripping leak; Oil is not on stick. Not enough oil to get sample.
Front Drive Axle Fluid Accumulation; Right side axle/universal is wet with buildup.
Rear Drive Axle Backhoe?
Final Drives
Limited Function Check The drivetrain was operational.
(2)


Hydraulics
Description Rating Details  
Pumps (Hydraulics) Fluid accumulation
Hydraulic Motors Fluid accumulation
Valves Fluid accumulation; Seepage
Hydraulic Tank
Hoses (Hydraulic)
Swing Motor Fluid accumulation; Seepage
Main Hoist
Auxiliary Hoist
Lift Cylinders Minor to moderate pin and bushing movement; Left cylinder has seepage.
Telescopic Boom Cylinders
Cylinder Pins and Bushings Minor to moderate movement
Limited Function Check The hydraulic system was operational without a load. See oil report.
(22)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Steering Linkage Minor to moderate movement
Outrigger Cylinders
Steering Wheel Play Minor to moderate movement
Brake Type Air
Master Cylinder/Brake Control Air compressor not visible
Park Brake Held against power; Stopped the machine while rolling
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Turntable Bearing Performs within tolerance expected for age and hours
Frame Condition
Tire Size 26.5-25 Front tires; 26.5-25 Rear tires; LF Toyo; LR Firestone; RR Toyo; RF Toyo
Tire Condition See photos
Tread Depth (4 tires) LF 8 mm; LR 5 mm; RR 15 mm; RF 13 mm
Wheel Condition
Wheel Studs
Limited Function Check The main chassis components were operational in a limited check.
Outrigger Condition
Outrigger Beams
Outrigger Floats/Pads Condition Bent; Cracks
Main Boom Pins Minimal movement
Main Boom Sections
Sheaves
Boom Head Section
Boom Extension Condition Three sections extended, 4th Section pin has to be removed extended and pin put back in place
Extension Chains / Cables Not visible
Wear Pads Minor to moderate movement
Boom Length 80' Extended boom length; 33' jib; 33' jib retracted
Boom Angle Indicator
Limited Function Check The main crane components functioned when checked without a load.
(58)


Specialty
Description Rating Details  
Jib 33' Long; Swing Away (side mounted)
Main Load Block None Supplied
Overhaul Ball
Counterweights 1 counterweights
(1)
 

Oil Sample Analysis
  Engine Hydraulic
date of analysis Dec 18, 2012 Dec 18, 2012
Silicon 4 PPM 11 PPM
Lead 3 PPM 2 PPM
Tin 0 PPM 1 PPM
Copper 279 PPM 23 PPM
Aluminum 2 PPM 6 PPM
Silver 0 PPM 0 PPM
Nickel 0 PPM 0.9 PPM
Chromium 1 PPM 2 PPM
Iron 9 PPM 12 PPM
Glycol NEG N/A
Water NEG NEG
Fuel <5% N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.