Previous Next
Sold on
6/8/23
Winning Bid
US $31,500
# of Bids
SOLD!
ITEM DETAILS
Meter Reading
11,501 Hours
Serial #
Dual Controls, CAT AS3251C Electric Heated 8 ft - 15 ft 5 in Screed, On Board Generator, 16 in Rubber Tracks

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Model Description
Description Details


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Some are rusted through Click here to open photos and videos of this item.  
Exterior Lights Some not operational Click here to open photos and videos of this item.  
(8)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Inoperable
Seat Belts Left side inoperable
Current Safety Manual No
Current Operator/Maintenance Manual No


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Some not responding Click here to open photos and videos of this item.  
Steering Control Right side wheel is bent Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure 47 PSI Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Screed Control Switches Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 11499.7 hrs Click here to open photos and videos of this item.  
Hour Meter 11501 hrs, Operational hour meter - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(20)


Engine
Description Rating Details  
Engine No US EPA Label Present
Emission Label Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) Significant ,Runs in high idle with black smoke, has no oil cap for engine had to use one from another machine to inspect, oil pushes out of cap if removed Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks Pushes out of cap, oil all over engine and under engine. Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Heavy black smoke in high idle Click here to open photos and videos of this item.  
(14)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational Click here to open photos and videos of this item.  
Left Drive Motor Click here to open photos and videos of this item.  
Right Drive Motor Click here to open photos and videos of this item.  
Left Final Drive Click here to open photos and videos of this item.  
Right Final Drive Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(5)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Hopper Wing Cylinders Click here to open photos and videos of this item.  
Screed Tow Point Cylinders Click here to open photos and videos of this item.  
Screed Lift Cylinders Click here to open photos and videos of this item.  
Screed Extension Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(17)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Screed Serial Number Serial Number: JJN00322 Click here to open photos and videos of this item.  
Screed Tow Arms Click here to open photos and videos of this item.  
Screed Bottom Plate Heavy Wear Click here to open photos and videos of this item.  
Hopper Wings Click here to open photos and videos of this item.  
Auger/ Screw Condition Broken both sides Click here to open photos and videos of this item.  
Feed Conveyors Click here to open photos and videos of this item.  
Conveyor Drive Chains and Sprockets Click here to open photos and videos of this item.  
Push Rollers Does not turn Click here to open photos and videos of this item.  
Truck Hitch Click here to open photos and videos of this item.  
Screed Heaters Not operationally checked, Generator is not functioning Click here to open photos and videos of this item.  
Screed Slope Adjustment Powered adjustment Click here to open photos and videos of this item.  
Screed Crown Adjustment Click here to open photos and videos of this item.  
Screed Tow Point Adjustment Powered adjustment, Does not operate right side Click here to open photos and videos of this item.  
Extension Tubes Click here to open photos and videos of this item.  
End Gates Click here to open photos and videos of this item.  
Spray Down System Not operationally checked Click here to open photos and videos of this item.  
Limited Function Check The main components were operational in a limited check., Frame is cracked right side back arm to steps
(29)


Rubber Track Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Left Roller Frame Click here to open photos and videos of this item.  
Left Track Tensioner Click here to open photos and videos of this item.  
Left Track Belt Condition Minor cuts Click here to open photos and videos of this item.  
Left Rubber Belt Drive Lugs Has damage Click here to open photos and videos of this item.  
Left Grouser Height Smooth Click here to open photos and videos of this item.  
Left Track Rollers Worn has damage Click here to open photos and videos of this item.  
Left Front Idler Click here to open photos and videos of this item.  
Left Sprocket Damage inside Click here to open photos and videos of this item.  
Right Roller Frame Click here to open photos and videos of this item.  
Right Track Tensioner Click here to open photos and videos of this item.  
Right Track Belt Condition Cuts Click here to open photos and videos of this item.  
Right Rubber Belt Drive Lugs Damage Click here to open photos and videos of this item.  
Right Track Rollers Click here to open photos and videos of this item.  
Right Front Idler Click here to open photos and videos of this item.  
Right Sprocket Click here to open photos and videos of this item.  
(19)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Jun 08, 2023 Jun 08, 2023
Silicon 9.57 PPM 5.13 PPM
Tin 0 PPM 0 PPM
Silver 0 PPM 0 PPM
Aluminum 1.36 PPM 1.85 PPM
Chromium 0.68 PPM 0.08 PPM
Lead 0.19 PPM 2.75 PPM
Copper 5.37 PPM 7.2 PPM
Nickel 0.32 PPM 0.38 PPM
Iron 15.95 PPM 13.91 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.