Previous Next
Ends
Subject to Offers
 
  
You will confirm this offer on the next page. How Make Offer works. How Make Offer works.
14 watchers
ITEM DETAILS
Meter Reading
157,170 Hours
Serial #
Air Conditioner, 335 ft Boom

***BUYERS NOTICE:

Any persons entering the mine to perform work will be required to be MSHA certified and ISNetworld compliant. Recommended companies for tear down of the dragline are Warfab and DSS-CAT (Dragline Service Specialties), both of which meet MSHA and ISNetworld requirements***

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark No CE mark found
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
General Appearance #1 Click here to open photos and videos of this item.  
(57)


Safety
Description Rating Details  
Horn Operational
Seat Belts Operational
Current Safety Manual Yes
Current Operator/Maintenance Manual Yes
(2)


Control Station - Upper
Description Rating Details  
Glass No visible damage Click here to open photos and videos of this item.  
Seats/Armrests Click here to open photos and videos of this item.  
Controls Hydraulic or Air Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter/Odometer 157170 hrs, Unit Is Still Running 24/7 - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner Operational
Heater Not operationally checked
Limited Function Check The main components are in place and operational as noted.
(16)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Click here to open photos and videos of this item.  
Limited Function Check (Drivetrain-Crawler Crane) The drivetrain functioned properly without a load. 16 ft x 80 ft Shoes
(23)


Crane Superstructure
Description Rating Details  
Hoist Drums Click here to open photos and videos of this item.  
Main Boom Pins Click here to open photos and videos of this item.  
Pendant Line (Boom Tension Line) Cable Type Click here to open photos and videos of this item.  
Point Sheaves Click here to open photos and videos of this item.  
Boom Point Section Click here to open photos and videos of this item.  
Gantry/Mast Click here to open photos and videos of this item.  
Main Boom Chords Click here to open photos and videos of this item.  
Boom Length 335 ft overall length Click here to open photos and videos of this item.  
Turntable Bearing Click here to open photos and videos of this item.  
Bottom Covers Click here to open photos and videos of this item.  
Swing Drive Operational Click here to open photos and videos of this item.  
Limited Function Check The main chassis components functioned when checked without a load.
(96)


Undercarriage
Description Rating Details  
Shoe Width Click here to open photos and videos of this item.  
(12)


Specialty
Description Rating Details  
Fairlead Click here to open photos and videos of this item.  
Counterweights Covered Click here to open photos and videos of this item.  
Dragline Bucket Click here to open photos and videos of this item.  
(13)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.