Previous Next
Sold on
10/15/26
Winning Bid
US $54,000
# of Bids
SOLD!
ITEM DETAILS
Meter Reading
7,675 Hours
Serial #
Dual Controls, Fume Extractor, 2016 US EPA Label, Requires Diesel Exhaust Fluid, weiler SE10 Electric Heated 10 ft - 19 ft 6 in Screed, On Board Generator, 18 in Rubber Tracks

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Model Description
Description Details


General Appearance
Description Rating Details  
CE Mark No CE mark found
Hour Meter / Odometer 7675 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(8)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat Belts Operational
Current Safety Manual No
Current Operator/Maintenance Manual No


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator remains on after engine is started. Click here to open photos and videos of this item.  
Warning Lights Operational
Screed Control Switches Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(10)


Engine
Description Rating Details  
US EPA Conformity Label 2016 US EPA Label, Requires Diesel Exhaust Fluid
Emission Label Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
DEF / AdBlue Tank Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(9)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational
Rear Drive Axle
Left Drive Motor Click here to open photos and videos of this item.  
Right Drive Motor Click here to open photos and videos of this item.  
Left Final Drive Click here to open photos and videos of this item.  
Right Final Drive Click here to open photos and videos of this item.  
Drive Chains/Sprockets Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(8)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Hopper Wing Cylinders Click here to open photos and videos of this item.  
Screed Tow Point Cylinders Click here to open photos and videos of this item.  
Screed Lift Cylinders Click here to open photos and videos of this item.  
Screed Extension Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(16)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Screed Serial Number No tag found
Screed Tow Arms Click here to open photos and videos of this item.  
Screed Bottom Plate Click here to open photos and videos of this item.  
Hopper Wings Click here to open photos and videos of this item.  
Auger/ Screw Condition Click here to open photos and videos of this item.  
Feed Conveyors Click here to open photos and videos of this item.  
Conveyor Drive Chains and Sprockets
Push Rollers Click here to open photos and videos of this item.  
Screed Heaters Not operationally checked, Units would not come on Click here to open photos and videos of this item.  
Screed Slope Adjustment Powered adjustment, Operational Click here to open photos and videos of this item.  
Screed Crown Adjustment Powered adjustment, Operational Click here to open photos and videos of this item.  
Screed Tow Point Adjustment Manual adjustment Click here to open photos and videos of this item.  
Mat Thickness Adjusters Powered adjustment Click here to open photos and videos of this item.  
Extension Tubes Click here to open photos and videos of this item.  
End Gates Click here to open photos and videos of this item.  
Spray Down System Not operationally checked Click here to open photos and videos of this item.  
Limited Function Check The main components were operational in a limited check.
(20)


Undercarriage
Description Rating Details  
Left Roller Frame Click here to open photos and videos of this item.  
Left Track Tensioner Click here to open photos and videos of this item.  
Left Rubber Track Belt Condition Click here to open photos and videos of this item.  
Left Rubber Belt Drive Lugs No visible damage Click here to open photos and videos of this item.  
Left Track Rollers Click here to open photos and videos of this item.  
Left Idler Click here to open photos and videos of this item.  
Left Sprocket Click here to open photos and videos of this item.  
Right Roller Frame Click here to open photos and videos of this item.  
Right Track Tensioner Click here to open photos and videos of this item.  
Right Rubber Track Belt Condition Click here to open photos and videos of this item.  
Right Rubber Belt Drive Lugs No visible damage Click here to open photos and videos of this item.  
Right Track Rollers Click here to open photos and videos of this item.  
Right Idler Click here to open photos and videos of this item.  
Right Sprocket Click here to open photos and videos of this item.  
(16)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Oct 08, 2026 Oct 08, 2026
Silicon 0 PPM 0 PPM
Tin 0.77 PPM 0.61 PPM
Silver 0 PPM 0 PPM
Aluminum 0.17 PPM 0 PPM
Chromium 0 PPM 0 PPM
Lead 0.58 PPM 3.19 PPM
Copper 0.64 PPM 15.28 PPM
Nickel 0.13 PPM 0.11 PPM
Iron 8.94 PPM 1.17 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.