Meter Reading
3,713 Hours
Serial #
Open Operator Station, 2006 US EPA Label, 73 in Bucket, 85 in Box Blade, Rear Frame Weights

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Hour Meter / Odometer 3713 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(21)


Safety
Description Rating Details  
Horn Operational
Seat Belts Operational
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Mirrors Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Hydraulic Controls Front loader joy stick heavy free play Click here to open photos and videos of this item.  
Auxiliary Hydraulic Control Click here to open photos and videos of this item.  
Drivetrain Controls Cover damaged around steering column, gear selector loose handle Click here to open photos and videos of this item.  
Dash Console Some damage Click here to open photos and videos of this item.  
Engine Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(18)


Engine
Description Rating Details  
Engine 2006 US EPA Label
Emission Label Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting. Click here to open photos and videos of this item.  
(7)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational Click here to open photos and videos of this item.  
Transfer Case / Drop Box Operational Click here to open photos and videos of this item.  
Front Drive Axle Click here to open photos and videos of this item.  
Front Axle Oscillating Pin Click here to open photos and videos of this item.  
Rear Drive Axle Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(9)


Hydraulics
Description Rating Details  
Pumps (Hydraulics)
Valves
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Some are damaged Click here to open photos and videos of this item.  
Loader Lift Cylinders Click here to open photos and videos of this item.  
Bucket Tilt Cylinders Click here to open photos and videos of this item.  
Steering Cylinders Both rubber boots damaged Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(19)


Chassis
Description Rating Details  
Steering Linkage Click here to open photos and videos of this item.  
Master Cylinder
Park Brake Stopped from a slow roll
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Frame Condition
Left Front Tire Click here to open photos and videos of this item.  
Left Rear Tire Click here to open photos and videos of this item.  
Right Rear Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs, Nuts, Lugs
Lift Arm Condition Click here to open photos and videos of this item.  
Chassis to Arm Pins Click here to open photos and videos of this item.  
Tilt Linkage Click here to open photos and videos of this item.  
Tilt Linkage Pins and Bushings Click here to open photos and videos of this item.  
Bucket to Arm Pins Click here to open photos and videos of this item.  
Limited Function Check The main components were operational except as noted.
(19)


Specialty
Description Rating Details  
Loader Bucket Condition Click here to open photos and videos of this item.  
Loader Bucket Cutting Edge Reversible-turned Click here to open photos and videos of this item.  
3-Point Linkage Click here to open photos and videos of this item.  
Counterweights Rear: Unknown amount Click here to open photos and videos of this item.  
Box Blade Click here to open photos and videos of this item.  
(15)
 

Oil Sample Analysis
  hydraulic
date of analysis Sep 18, 2026
Silicon 5.25 PPM
Tin 4.16 PPM
Silver 0.02 PPM
Aluminum 1.7 PPM
Chromium 0.44 PPM
Lead 8.7 PPM
Copper 5.25 PPM
Nickel 0.25 PPM
Iron 24.65 PPM
Glycol N/A
Water N/A
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.