Previous Next
Sold on
2/19/26
Winning Bid
US $2,700
# of Bids
SOLD!
ITEM DETAILS
Meter Reading
4,583 Hours
Serial #
18 ft 6 in Stick, 11.00x20 Tires, 52 in Cleanup Bucket

Inspection Report



Please note that you are bidding on an item offered without IronClad Assurance®. Only basic item condition details are provided for your review and consideration in a purchase decision.
 
Deficiencies
Description Details
Deficiencies Deficient Components/Systems Include but are not limited to: Has a bad air leak. Will not build enough air to release brakes

This item is offered as-is, where-is with no IronClad Assurance, and a buyer may not dispute the condition of the item. IronPlanet claims no responsibility for the condition or description of this item. This item does not include any protection offered by IronClad Assurance. A buyer may NOT submit a dispute claim on this item.


General Appearance
Description Rating Details  
Hour Meter / Odometer 4583 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Indication of Additional Hours There is a tag between the odometer and the hour meter that has 4500. It was uncertain if these were additional hours. Click here to open photos and videos of this item.  
(4)


Control Station
Description Rating Details  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(11)


Engine
Description Rating Details  
Engine No US EPA Label Present
Limited Function Check After jump starting, the engine ran. Click here to open photos and videos of this item.  
(6)


Drivetrain
Description Rating Details  
Limited Function Check The drivetrain was operational. Transmission will engage but has a bad air leak and will not release the brakes for function test
(2)


Brakes
Description Rating Details  
Brakes The brakes could not be operationally checked. Bad air leak. Park brake will not release


Hydraulics
Description Rating Details  
Limited Function Check The hydraulic system was not operational.
(4)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
(8)


Specialty
Description Rating Details  
(3)
 
Oil Sample Analysis
Oil sample analysis not available.
NON-DISPUTABLE