Previous Next
Sold on
1/15/26
Winning Bid
US $16,000
# of Bids
2
SOLD!
ITEM DETAILS
Meter Reading
See Report
Serial #
Yanmar 3TNM74F-SAAY 3 Cylinder Diesel Engine, 36 ft Reach, 12 in Rubber Tracks

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Unit Serial Number Click here to open photos and videos of this item.  
CE Mark No CE mark found
Hour Meter / Odometer - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Indication of Additional Hours There is an hour meter replacement/change label that has the following reading on it: 177 Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
(10)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Gauges Operational Click here to open photos and videos of this item.  
Engine Oil Pressure No oil pressure indicator
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(9)


Engine
Description Rating Details  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting. Click here to open photos and videos of this item.  
(8)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Limited Function Check The drivetrain was operational.
(4)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Not operationally checked, Front, Rear Click here to open photos and videos of this item.  
Cylinder(s) Click here to open photos and videos of this item.  
Cylinder Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(26)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Condition Click here to open photos and videos of this item.  
(21)


Undercarriage
Description Rating Details  
(16)


Trailer Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.