Previous Next
Sold on
6/26/25
Winning Bid
US $9,500
# of Bids
2
SOLD!
ITEM DETAILS
Meter Reading
1,500 Hours
Serial #
Enclosed Cab, Air Conditioner, 20.5-25 Tires, Water Cannon, Front Spray, Rear Spray, Hydraulic Driven Water Pump

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Hour Meter / Odometer 1500 hrs, Meter inoperable - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Not operational Click here to open photos and videos of this item.  
(13)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Inoperable
Seat Belts Operational
Current Safety Manual No
Current Operator/Maintenance Manual No
(3)


Control Station
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure No oil pressure indicator
Warning Lights Inoperable Click here to open photos and videos of this item.  
Gauges Click here to open photos and videos of this item.  
Air Conditioner Inoperable
Heater Not operationally checked Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(19)


Engine
Description Rating Details  
Engine No US EPA Label Present
Emission Label Click here to open photos and videos of this item.  
A/C Compressor Compressor will not engage Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting. Unable to shut engine down with reverse throttle.
(9)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Type 5 Speed, Powershift
Transmission Operational Click here to open photos and videos of this item.  
Front Axle Assembly Dripping leak Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check - Scraper The drivetrain was operational without a load.
(15)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Steering Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(9)


Chassis
Description Rating Details  
Hitch Condition Click here to open photos and videos of this item.  
Hitch Pin Condition Click here to open photos and videos of this item.  
Suspension System Click here to open photos and videos of this item.  
Frame Condition Click here to open photos and videos of this item.  
Limited Function Check The main chassis components functioned during a limited check.
Master Cylinder Click here to open photos and videos of this item.  
Brake Control Click here to open photos and videos of this item.  
Brake Lines/Hoses
Park Brake Inoperable
Limited Function Check - Brakes The service brakes were operational. Park break in operational
Tire Condition Bias ply Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs, Nuts, Lugs
Tank Condition The tank is dented. Click here to open photos and videos of this item.  
Water Pump Not operationally checked, Hydraulic seepage. Click here to open photos and videos of this item.  
Baffles
Water Valves Not operationally checked Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Limited Function Check The components that could be checked functioned with wear.
(43)
 

Oil Sample Analysis
  hydraulic engine
Aluminum 0.83 PPM 3.32 PPM
Chromium 0 PPM 0.99 PPM
Copper 2.55 PPM 5.9 PPM
date of analysis Jun 17, 2025 Jun 17, 2025
Fuel N/A <5%
Glycol N/A NEG
Iron 3.18 PPM 27.51 PPM
Lead 0 PPM 1.08 PPM
Nickel 0.04 PPM 0.25 PPM
Silicon 5.33 PPM 13.66 PPM
Silver 0 PPM 0 PPM
Tin 0 PPM 0 PPM
Water N/A NEG
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.