Previous Next
Auction Closed on
6/19/25
Opened At
CAD 57,000
NOT SOLD
7 watchers
ITEM DETAILS
Meter Reading
12,617 Hours
Serial #
Enclosed Cab, Air Conditioner, 2006 US EPA Label, Auxiliary Hydraulics, 96 in Multi-Purpose Bucket, 20 in Double Grouser Track Shoes, SystemOne Undercarriage

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Hour Meter / Odometer 12617 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(10)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat Belts Operational
Safety Lock Out/Stop Operational Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
3rd Valve Equipped with a 3rd valve and plumbing for an auxiliary attachment. Click here to open photos and videos of this item.  
Steering Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Air Conditioner The ambient temperature is too cold to check.
Heater Operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(10)


Engine
Description Rating Details  
Engine 2006 US EPA Label
Emission Label Click here to open photos and videos of this item.  
A/C Compressor In place; ambient temperature too cold to check operation Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(11)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational Click here to open photos and videos of this item.  
Service Brakes
Final Drives Click here to open photos and videos of this item.  
Limited Function Check (Drivetrain-Track) The drivetrain was operational without a load.
(4)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics)
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulic) Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Operational, Front Click here to open photos and videos of this item.  
Loader Lift Cylinders Click here to open photos and videos of this item.  
Bucket Tilt Cylinders Click here to open photos and videos of this item.  
Multi Purpose Bucket Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(12)


Chassis
Description Rating Details  
Frame Condition Click here to open photos and videos of this item.  
Belly Pans Click here to open photos and videos of this item.  
(2)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Lift Arm Condition Click here to open photos and videos of this item.  
Chassis to Arm Pins Click here to open photos and videos of this item.  
Tilt Linkage Click here to open photos and videos of this item.  
Tilt Linkage Pins and Bushings Click here to open photos and videos of this item.  
Bucket to Arm Pins Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
(9)


Specialty
Description Rating Details  
Loader Bucket Condition Click here to open photos and videos of this item.  
Loader Bucket Cutting Edge Reversible-not turned Click here to open photos and videos of this item.  
(2)


Undercarriage
Description Rating Details  
Left Roller Frame Click here to open photos and videos of this item.  
Left Track Tensioner Click here to open photos and videos of this item.  
Left Track Pads Click here to open photos and videos of this item.  
Left Grouser Height 32 mm Click here to open photos and videos of this item.  
Left Track Links Click here to open photos and videos of this item.  
Left Track Bushings Bushings have not been turned Click here to open photos and videos of this item.  
Left Carrier Rollers Click here to open photos and videos of this item.  
Left Track Rollers Click here to open photos and videos of this item.  
Left Idler Click here to open photos and videos of this item.  
Left Sprocket Click here to open photos and videos of this item.  
Right Roller Frame Click here to open photos and videos of this item.  
Right Track Tensioner Click here to open photos and videos of this item.  
Right Track Pads Click here to open photos and videos of this item.  
Right Grouser Height 25 mm Click here to open photos and videos of this item.  
Right Track Links Click here to open photos and videos of this item.  
Right Track Bushings Bushings have not been turned Click here to open photos and videos of this item.  
Right Carrier Rollers Click here to open photos and videos of this item.  
Right Track Rollers Click here to open photos and videos of this item.  
Right Idler Click here to open photos and videos of this item.  
Right Sprocket Click here to open photos and videos of this item.  
(20)
 

Oil Sample Analysis
  engine
date of analysis May 03, 2025
Silicon 19.45 PPM
Tin 0 PPM
Silver 0 PPM
Aluminum 4.28 PPM
Chromium 0.52 PPM
Lead 0.25 PPM
Copper 1.88 PPM
Nickel 0 PPM
Iron 26.36 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.