Previous Next
Sold on
3/27/25
Winning Bid
US $6,500
# of Bids
SOLD!
ITEM DETAILS
Meter Reading
7,368 Hours
Serial #
Dual Controls, Fume Extractor, Requires Diesel Exhaust Fluid, Carlson paving products. EZV10 Electric Heated 10 ft - 19 ft Screed, On Board Generator, Front Wheel Assist

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Model Description
Description Details


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Chassis #35 Click here to open photos and videos of this item.  
(1)


General Appearance
Description Rating Details  
Hour Meter / Odometer 7368 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Some not operational, Side lights not operational lights are not operational Click here to open photos and videos of this item.  
(6)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Inoperable
Seat Belts Operational
Safety Lock Out/Stop Operational Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Screed harnesses unplugged and jumped. Otherwise the unit will not start and run. Screed not operationally checked. Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure The gauge registers in the operating range. 54 PSI Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Screed Control Switches Click here to open photos and videos of this item.  
Gauges Operational, Right side instrument cluster screen not operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Screed harnesses unplugged and jumped. Otherwise the unit will not start and run. Screed not operationally checked. Click here to open photos and videos of this item.  
(19)


Engine
Description Rating Details  
Engine No US EPA Label Present Requires Diesel Exhaust Fluid
Emission Label No label found
Blow-by (subjective visual observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
DEF / AdBlue Tank Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(16)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Left Drive Motor
Right Drive Motor
Left Final Drive Dripping Leak, Wet with fluid? Click here to open photos and videos of this item.  
Right Final Drive Fluid seepage Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(4)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Unable to fully inspect. Screed harnesses unplugged and jumped. Otherwise the unit will not start and run. Screed not operationally checked. Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Hopper Wing Cylinders Click here to open photos and videos of this item.  
Steering Cylinders Click here to open photos and videos of this item.  
Screed Tow Point Cylinders Click here to open photos and videos of this item.  
Screed Lift Cylinders Click here to open photos and videos of this item.  
Screed Extension Cylinders Screed harnesses unplugged and jumped. Otherwise the unit will not start and run. Screed not operationally checked. Click here to open photos and videos of this item.  
Screed Vibrators Screed harnesses unplugged and jumped. Otherwise the unit will not start and run. Screed not operationally checked. Click here to open photos and videos of this item.  
Limited Function Check hydraulic system not fully inspected as there are electrical problems with the screed.
(26)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Screed Serial Number Serial Number: 139VB7S Click here to open photos and videos of this item.  
Screed Tow Arms Click here to open photos and videos of this item.  
Screed Bottom Plate Click here to open photos and videos of this item.  
Hopper Wings Click here to open photos and videos of this item.  
Metering Gates Powered, Right gate bent Click here to open photos and videos of this item.  
Auger/ Screw Condition Click here to open photos and videos of this item.  
Feed Conveyors Click here to open photos and videos of this item.  
Conveyor Drive Chains and Sprockets Click here to open photos and videos of this item.  
Push Rollers Click here to open photos and videos of this item.  
Screed Heaters Not operationally checked Click here to open photos and videos of this item.  
Screed Slope Adjustment Screed harnesses unplugged and jumped. Otherwise the unit will not start and run. Screed not operationally checked. Click here to open photos and videos of this item.  
Screed Crown Adjustment Not operationally checked Click here to open photos and videos of this item.  
Screed Tow Point Adjustment Not operationally checked Click here to open photos and videos of this item.  
Mat Thickness Adjusters Operational Click here to open photos and videos of this item.  
Extension Tubes Click here to open photos and videos of this item.  
End Gates Not fully inspected as they do not respond to controls. Click here to open photos and videos of this item.  
Spray Down System Not operationally checked Click here to open photos and videos of this item.  
Front Tire/Wheel Condition Click here to open photos and videos of this item.  
Rear Wheel Condition Click here to open photos and videos of this item.  
Rear Tire Condition Minor cuts and gouges Click here to open photos and videos of this item.  
Wheel Studs
Limited Function Check The unit could not be started. Some components could not be checked., No response from screed controls. Technician states unit has an electrical problem. Screed harnesses unplugged jumpers installed in order to start and move unit.
(34)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.