ITEM DETAILS
Meter Reading
486 Hours
Serial #
20 in Working Width, Water System, Rear Squeegee, Mitsubishi 4 Cylinder 2.0 L Dual Fuel Engine, LP Tank is not included

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Model Description
Description Details


General Appearance
Description Rating Details  
Hour Meter / Odometer 486 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
(7)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Operational
Seat Belts Operational
Current Safety Manual No
Current Operator/Maintenance Manual No


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Gauges Operational Click here to open photos and videos of this item.  
Engine Oil Pressure No oil pressure indicator
Warning Lights Operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(8)


Engine
Description Rating Details  
Emission Label Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Fuel System Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(11)


Electric Operating System
Description Rating Details  
Operating Voltage 12 Volts
Battery Condition Functioned during the inspection
Cables and Connections Click here to open photos and videos of this item.  
Limited Function Check The electrical system was operational.
(1)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Vacuum Pump
Vacuum Drive Hydrostatic Drive
Debris Tank Fully Opening Rear Door, Manual Door Locks Click here to open photos and videos of this item.  
Main Broom Click here to open photos and videos of this item.  
Suction Hoses Click here to open photos and videos of this item.  
Water Tank Click here to open photos and videos of this item.  
Pressure Pump - Water
Limited Function Check The main components were operational when checked without a load.
(4)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Hydraulic Motors
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Cylinder(s) Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(5)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.