Previous Next
Ends
Subject to Offers
High Offer
CAD 75,000
 
  
Buy Now Price
CAD 115,000
You will confirm this action on the next page. How it works. How Make Offer works.
ITEM DETAILS
Meter Reading
6 Hours
Serial #
2-Maxfield 1000 GAL Baffled propane tanks, skid mounted. Westquip Diesel rig-up, - Stamford 105 kW Main Generator, Stamford 117 kW Backup Generator , (4) Lamp Light Tower Mast, 9850 L Generator Fuel Tank, x(2) 2014 Isuzu B1-4HK1X diesel engines, Main Gen 480 Volt 3Phase 105 Kw, Backup Gen 120 / 208 Volt 3 Phase 117 Kw

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Hour Meter / Odometer 6 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
(6)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Gauges Operational, 85 gauges are inoperable Click here to open photos and videos of this item.  
Engine Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(6)


Generator Platform
Description Rating Details  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Operational Click here to open photos and videos of this item.  
Receptacles Operational Click here to open photos and videos of this item.  
Power Generation The main components appear to be in place. The generator is producing electrical current.
(3)
 

Oil Sample Analysis
  engine
Aluminum 1.89 PPM
Chromium 0.26 PPM
Copper 9.83 PPM
date of analysis Feb 19, 2025
Fuel <5%
Glycol NEG
Iron 5.43 PPM
Lead 0.84 PPM
Nickel 0 PPM
Silicon 15.38 PPM
Silver 0 PPM
Tin 2.74 PPM
Water NEG
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.