Previous Next
Sold on
9/8/25
Winning Offer
US $41,500
# of Offers
# of Watchers
50
SOLD!
ITEM DETAILS
Meter Reading
9,357 Hours
Serial #
Enclosed Cab, Air Conditioner, 2006 US EPA Label, 100 in Bucket, 2 Cylinder Multi-Shank Ripper, 23 in Double Grouser Track Shoes

TODAY'S PRICE: $60,000 $70,000 14% OFF


Click here to shop for more discounted items

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark No CE mark found
Hour Meter / Odometer 9357 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Exterior Lights Some not operational, 1 rear inoperable lights are not operational Click here to open photos and videos of this item.  
(16)


Safety
Description Rating Details  
Horn Operational
Seat Belts Operational
Current Safety Manual No
Current Operator/Maintenance Manual No


Control Station
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Seats/Armrests The seat cover and cushion are damaged. Click here to open photos and videos of this item.  
Control Lock Lever
Hydraulic Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Warning Lights Operational, transmission light flashes. light stays on Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Air Conditioner The ambient temperature is too cold to check.
Heater Inoperable, The temperature control knob is stuck. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Left door release button missing. Click here to open photos and videos of this item.  
(19)


Engine
Description Rating Details  
Engine 2006 US EPA Label
Emission Label Click here to open photos and videos of this item.  
A/C Compressor In place; ambient temperature too cold to check operation Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. The engine has a misfire. Click here to open photos and videos of this item.  
(17)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational Click here to open photos and videos of this item.  
Service Brakes
Drive Motors
Final Drives Click here to open photos and videos of this item.  
Limited Function Check (Drivetrain-Track) The drivetrain was operational without a load.
(5)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics)
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulic) Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Capped off, Front Click here to open photos and videos of this item.  
Loader Lift Cylinders Click here to open photos and videos of this item.  
Bucket Tilt Cylinders Click here to open photos and videos of this item.  
Ripper Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(10)


Chassis
Description Rating Details  
Frame Condition Click here to open photos and videos of this item.  
Belly Pans Click here to open photos and videos of this item.  
(2)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Lift Arm Condition Click here to open photos and videos of this item.  
Chassis to Arm Pins Click here to open photos and videos of this item.  
Tilt Linkage Click here to open photos and videos of this item.  
Tilt Linkage Pins and Bushings Click here to open photos and videos of this item.  
Bucket to Arm Pins Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
(8)


Specialty
Description Rating Details  
Loader Bucket Condition Click here to open photos and videos of this item.  
Loader Bucket Cutting Edge Click here to open photos and videos of this item.  
Loader Bucket Shanks and Teeth Click here to open photos and videos of this item.  
Ripper Condition Click here to open photos and videos of this item.  
Ripper Shanks and Teeth Click here to open photos and videos of this item.  
(12)


Undercarriage
Description Rating Details  
Left Roller Frame Click here to open photos and videos of this item.  
Left Track Tensioner Click here to open photos and videos of this item.  
Left Track Pads Click here to open photos and videos of this item.  
Left Grouser Height 39 mm Click here to open photos and videos of this item.  
Left Track Links Click here to open photos and videos of this item.  
Left Track Bushings Rotating Bushings Click here to open photos and videos of this item.  
Left Carrier Rollers Click here to open photos and videos of this item.  
Left Track Rollers Click here to open photos and videos of this item.  
Left Idler Click here to open photos and videos of this item.  
Left Sprocket Click here to open photos and videos of this item.  
Right Roller Frame Click here to open photos and videos of this item.  
Right Track Tensioner Click here to open photos and videos of this item.  
Right Track Pads Click here to open photos and videos of this item.  
Right Grouser Height 39 mm Click here to open photos and videos of this item.  
Right Track Links Click here to open photos and videos of this item.  
Right Track Bushings Rotating Bushings Click here to open photos and videos of this item.  
Right Carrier Rollers Click here to open photos and videos of this item.  
Right Track Rollers Click here to open photos and videos of this item.  
Right Idler Click here to open photos and videos of this item.  
Right Sprocket Click here to open photos and videos of this item.  
(28)
 

Oil Sample Analysis
  transmission engine
Aluminum 2.05 PPM 0.83 PPM
Chromium 0.28 PPM 0.04 PPM
Copper 0.39 PPM 0.22 PPM
date of analysis Jan 15, 2025 Jan 15, 2025
Fuel N/A <5%
Glycol N/A NEG
Iron 30.68 PPM 7.06 PPM
Lead 0.78 PPM 0.78 PPM
Nickel 0.98 PPM 0.91 PPM
Silicon 14.66 PPM 3.29 PPM
Silver 0 PPM 0 PPM
Tin 0.28 PPM 1.11 PPM
Water N/A NEG
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.