ITEM DETAILS
Meter Reading
144 Hours
Serial #
200 Volts 3 Phase, 120V / 240V Receptacles, Kohler Engine, Fuel Tank, Stationary, Stick, 1 Station Welding Machine

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Front lower cover rusted Click here to open photos and videos of this item.  
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
(10)


Control Station
Description Rating Details  
Oil Pressure No oil pressure indicator
Hour Meter (pre-inspection) 144.0 Hours Click here to open photos and videos of this item.  
Hour Meter 144.1 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
(2)


Engine
Description Rating Details  
Fuel Type Gasoline
Emission Certification Label Both EPA and EC certification Click here to open photos and videos of this item.  
Blow by @ idle (subjective visual observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Fuel System Operational
Exhaust System Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) After jump starting, the engine ran. Click here to open photos and videos of this item.  
(7)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator Make and Model Click here to open photos and videos of this item.  
Disconnect Switch Functional Click here to open photos and videos of this item.  
Cables and Connections No cables attached
Receptacles Operational Click here to open photos and videos of this item.  
Limited Function Check The main components appear to be in place. The generator is producing electricity.
(13)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Related Equipment (Both Live and Sold)
120/240 Volts Single Phase, 120V & 240V Receptacles, ...
120/240 Volts Single Phase, 120V & 240V Receptacles, Kohler Engine, TIG, Stick The engine was unable to be started. The main components could not be operationally checked. ***The propane tank is NOT included***
Kohler Engine, 9.5 kW, 120V Receptacles & 240V ...
Kohler Engine, 9.5 kW, 120V Receptacles & 240V Receptacles, S/A, Stick, TIG, LP Tank is not included
120V Receptacles, 240V Receptacles, Kohler LP Engine, TIG, ...
120V Receptacles, 240V Receptacles, Kohler LP Engine, TIG, Stick, Portable, LP Tank is not included The engine cranks but will not start. The main components could not be operationally checked.
11 kVA, 240 Volts Single Phase, 120V & ...
11 kVA, 240 Volts Single Phase, 120V & 240V Receptacles, Kohler Engine, MIG, TIG, Stick, Portable ***The LP tank is NOT included***