ITEM DETAILS
Meter Reading
2,434 Hours
Serial #
Enclosed Cab, 43 ft 0 in Max Lift Height, 9000 lb Max Lift Capacity, 2006 US EPA Label, Frame Leveling, Auxiliary Hydraulic Plumbing

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(5)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Inoperable
Seat Belts Operational


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Load Charts Chart book in cab Click here to open photos and videos of this item.  
Engine Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Fuel gauge inoperable Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 2434.2 hrs Click here to open photos and videos of this item.  
Hour Meter 2434 hrs, Operational hour meter - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner Inoperable, Controls in cab for heat/air inoperable
Heater Not operationally checked
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(16)


Engine
Description Rating Details  
Engine 2006 US EPA Label
Emission Label Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(11)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational Click here to open photos and videos of this item.  
Transfer Case / Drop Box Operational Click here to open photos and videos of this item.  
Front Drive Axle Click here to open photos and videos of this item.  
Front Axle Oscillating Pin Click here to open photos and videos of this item.  
Rear Drive Axle Click here to open photos and videos of this item.  
Rear Axle Oscillating Pin Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(10)


Hydraulics
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Pinched hose for auxiliary plumbing connection Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Not operationally checked, Front Click here to open photos and videos of this item.  
Boom Lift Cylinder(s) Dripping leak Click here to open photos and videos of this item.  
Telescopic Boom Cylinders
Carriage Tilt Cylinder Click here to open photos and videos of this item.  
Frame Leveling Cylinders Click here to open photos and videos of this item.  
Steering Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(14)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Boom Condition Click here to open photos and videos of this item.  
Left Side of Boom Click here to open photos and videos of this item.  
Right Side of Boom Click here to open photos and videos of this item.  
Chain / Tensioners
Boom Wear Guides Click here to open photos and videos of this item.  
Steering Linkage Click here to open photos and videos of this item.  
Frame Condition Click here to open photos and videos of this item.  
Limited Function Check The main chassis components functioned during a limited check.
Master Cylinder
Brake Control
Brake Lines/Hoses
Park Brake
Limited Function Check - Brakes The service brakes are operational, The park brake is operational.
Tire Brands Left Front: Solideal , Left Rear: Solideal, Right Rear: solideal, Right Front: Camso
Left Front Tire Click here to open photos and videos of this item.  
Left Rear Tire Click here to open photos and videos of this item.  
Right Rear Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs, Nuts, Lugs
(11)


Specialty
Description Rating Details  
Forks None included in sale
 

Oil Sample Analysis
  engine hydraulic
date of analysis Mar 01, 2023 Mar 01, 2023
Silicon 12.96 PPM 3.27 PPM
Tin 0 PPM 0 PPM
Silver 0 PPM 0 PPM
Aluminum 1.27 PPM 1.21 PPM
Chromium 0.4 PPM 0.23 PPM
Lead 0 PPM 0.39 PPM
Copper 1.93 PPM 68.92 PPM
Nickel 0.8 PPM 0.86 PPM
Iron 12.58 PPM 2.76 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.