Previous Next
Sold on
2/4/21
Winning Bid
US $8,170
# of Bids
SOLD!
ITEM DETAILS
Meter Reading
See Report
Serial #
60 in Scrubber, Rear Squeegee, 2.0L Gasoline, LPG or NG Engine, Open Operator Station

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Model Description
Description Details


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
(8)


Features
Description Rating Details  
Features Open Operator Station, 60" Scrubber, Rear Squeegee, 2.0L Gasoline, LPG or NG Engine


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Operational
Seat Belts Operational
Current Safety Manual No
Current Operator/Maintenance Manual No


Control Station
Description Rating Details  
Engine Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Warning Lights Operational
Hour Meter (pre-inspection) Can’t Read
Hour Meter Unknown total hours - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(4)


Engine
Description Rating Details  
Emission Label Click here to open photos and videos of this item.  
Starter Operational
Fuel System Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check The engine started and ran. Click here to open photos and videos of this item.  
(10)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive/Propel Motors Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(3)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Vacuum Pump Click here to open photos and videos of this item.  
Vacuum Drive Belt Drive Click here to open photos and videos of this item.  
Debris Tank Fully Opening Rear Door Click here to open photos and videos of this item.  
Water Tank Not operationally checked Click here to open photos and videos of this item.  
Limited Function Check The main components were operational when checked without a load.
(9)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Cylinder(s) Click here to open photos and videos of this item.  
Cylinder Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(13)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Related Equipment (Both Live and Sold)
The unit was not operationally checked. ...
Walk-Behind, 30” Scrubber, Water System, Rear Squeegee, 36 ...
Walk-Behind, 30” Scrubber, Water System, Rear Squeegee, 36 Volt Operating SystemThe electric system was operational. The drivetrain engaged in forward and reverse. The main components appear to be in place and operational.
Walk-Behind, Water System, Rear Squeegee, 36 Volt Operating ...
Walk-Behind, Water System, Rear Squeegee, 36 Volt Operating SystemThe electrical system was operational. The drivetrain engaged in forward and reverse.
Water System, Scrubber, Battery Operated Unit has been ...
Water System, Scrubber, Battery Operated Unit has been partially disassembled