Previous Next
Sold on
4/25/19
Winning Bid
US $8,000
# of Bids
3
SOLD!
ITEM DETAILS
Meter Reading
2,400 Hours
Serial #
Enclosed Cab, Heater, Auxiliary Hydraulic Plumbing, Manual Coupler, 80" Wide General Purpose Smooth Edge Bucket

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(15)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Inoperable
Seat Belts Operational
Safety Lock Out/Stop Operational Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Engine Controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 2,400.4 Hours Click here to open photos and videos of this item.  
Hour Meter 2,400.4 Hours; Inoperable hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Heater Operational
Limited Function Check The main components are in place and operational as noted. Unit creeps forward at startup on occasion (approx. 3”) Click here to open photos and videos of this item.  
(11)


Engine
Description Rating Details  
Emission Certification Label None found
Blow by @ idle (subjective observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Oil cooled Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks No dripping leaks Click here to open photos and videos of this item.  
Cooling System Leaks No dripping leaks Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) After jump starting, the engine ran. Click here to open photos and videos of this item.  
(10)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors
Limited Function Check The drivetrain was operational.
(2)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics)
Valves
Hydraulic Tank Low level Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Click here to open photos and videos of this item.  
Loader Lift Cylinders Click here to open photos and videos of this item.  
Bucket Tilt Cylinders Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(6)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Condition Click here to open photos and videos of this item.  
Belly pans Click here to open photos and videos of this item.  
Left Front Tire Click here to open photos and videos of this item.  
Left Rear Tire Click here to open photos and videos of this item.  
Right Rear Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs
Lift Arm Condition Click here to open photos and videos of this item.  
Chassis to Arm Pins Click here to open photos and videos of this item.  
Quick Coupler to Arms Pins Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
(16)


Specialty
Description Rating Details  
Quick Coupler Not operational Click here to open photos and videos of this item.  
Loader Bucket Condition Click here to open photos and videos of this item.  
Loader Bucket Cutting Edge/Shanks/Teeth New edge; Reversible-not turned Click here to open photos and videos of this item.  
(9)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Apr 23, 2019 Apr 23, 2019
Silicon 65.86 PPM 12.8 PPM
Tin 0 PPM 0 PPM
Silver 0 PPM 0 PPM
Aluminum 15.86 PPM 4.19 PPM
Chromium 4.34 PPM 0.59 PPM
Lead 0 PPM 0 PPM
Copper 13.56 PPM 13.67 PPM
Nickel 1.74 PPM 0.88 PPM
Iron 170.09 PPM 33.01 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Related Equipment (Both Live and Sold)
The item appears to be generally complete. Seller ...
The item appears to be generally complete. Seller comments: Seller comments: Fits Skid-Steer Loader *** Click on the link below for Seller Supplied Brochure ***
Open Operator Station, Auxiliary Hydraulic Plumbing, Solid Tires, ...
Open Operator Station, Auxiliary Hydraulic Plumbing, Solid Tires, 36" Wide General Purpose Smooth Edge Bucket, Manual CouplerThere was no response from the engine when the key was turned. The main components could not be operationally checked.
Enclosed Cab (Door missing), Air Conditioner, Heater, Auxiliary ...
Enclosed Cab (Door missing), Air Conditioner, Heater, Auxiliary Hydraulic Plumbing, Electrical Connection at Auxiliary Hydraulic Ports, Two Speed, Cushion Tires, Hydraulic Coupler, 80" General Purpose Bucket w/ Teeth
Open Operator Station, Auxiliary Hydraulic Plumbing, Vertical Lift, ...
Open Operator Station, Auxiliary Hydraulic Plumbing, Vertical Lift, Solid Tires, Manual Coupler, 80" Wide General Purpose Smooth Edge Bucket, Ultra Low Sulfur Diesel