ITEM DETAILS
Meter Reading
20,978 Hours
Serial #
750 kVA/600 kW Rated 3 Phase Output, 480 V Rated Voltage, Sound Attenuated, Cat SR4B 600 kW Generator, 2001 US EPA Label, Cat 3412 12 Cylinder 913 hp 27 L Diesel Engine, Air Brakes


**No Title available. Bill of Sale will be provided upon request to convey ownership**

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Unit Serial Number 9FG02427 Click here to open photos and videos of this item.  
Hour Meter / Odometer 20978 hrs - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
(6)


Generator
Description Rating Details  
Disconnect Switch Not operationally checked Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Not operationally checked Click here to open photos and videos of this item.  
Receptacles Not operationally checked Click here to open photos and videos of this item.  
Power Generation The main components appear to be in place. The generator is producing electrical current.
(8)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Gauges Operational Click here to open photos and videos of this item.  
Engine Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(4)


Engine
Description Rating Details  
Emission Label Click here to open photos and videos of this item.  
Blow-by (subjective visual observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Fuel System Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Cooling System Leaks Radiator hose Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting. Click here to open photos and videos of this item.  
(13)


Trailer Chassis
Description Rating Details  
Axle Condition Click here to open photos and videos of this item.  
Brake Type Air Brakes
Limited Function Check - Brakes The brakes were not operationally checked, The park brake is operational.
Left Front Tire Click here to open photos and videos of this item.  
Left Rear Tire Click here to open photos and videos of this item.  
Right Rear Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs
Springs/Hangers Condition Click here to open photos and videos of this item.  
Tongue/ Hitch Condition No visible damage Click here to open photos and videos of this item.  
Lights/Wiring Condition Not operationally checked Click here to open photos and videos of this item.  
Frame Rails/ Main Beams Condition No visible damage Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Fuel Tank Condition Click here to open photos and videos of this item.  
(17)
 

Oil Sample Analysis
  hydraulic
Aluminum 1.46 PPM
Chromium 0.1 PPM
Copper 22.85 PPM
date of analysis Oct 06, 2025
Fuel N/A
Glycol N/A
Iron 3.55 PPM
Lead 1.39 PPM
Nickel 0.14 PPM
Silicon 3.21 PPM
Silver 0 PPM
Tin 0.09 PPM
Water N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.