Meter Reading
9,219 Hours
Serial #
145 kVA, 116 kW, 480/208 Volts 3 Phase, 240 Volts Single Phase, 120V Receptacles, 240V Receptacles, John Deere Engine, Bottom Mounted Fuel Tank, Skid Mounted, Insulated Enclosure, Stationary

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark Yes Click here to open photos and videos of this item.  
(3)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Gauges Operational
Oil Pressure Click here to open photos and videos of this item.  
Warning Lights Operational
Hour Meter (pre-inspection) 9,219.0 Hours Click here to open photos and videos of this item.  
Hour Meter 9219.4 Hours; Operational hour meter - No guarantees made as to actual hours/miles/kilometers; the inspection report reflects what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted. Click here to open photos and videos of this item.  
(4)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Certification Label US EPA certification label Click here to open photos and videos of this item.  
Blow by @ idle (subjective visual observation) Recirculating system
Starter Operational
Fuel System Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator
Oil Leaks No dripping leaks
Fuel Leaks No dripping leaks
Cooling System Leaks No dripping leaks
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) After jump starting, the engine ran. The unit shut down after running for a few minutes. Click here to open photos and videos of this item.  
(8)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Disconnect Switch Not operationally checked Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Operational Click here to open photos and videos of this item.  
Receptacles Not operationally checked Click here to open photos and videos of this item.  
Limited Function Check The unit shuts down after a few minutes of running. The electrical system was not able to be operationally checked.
(8)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Rails/ Main Beams Condition No visible damage Click here to open photos and videos of this item.  
Fuel Tank Condition Click here to open photos and videos of this item.  
(2)
 

Oil Sample Analysis
  engine
date of analysis Jan 30, 2019
Silicon 0 PPM
Tin 0 PPM
Silver 0.03 PPM
Aluminum 0.82 PPM
Chromium 0.12 PPM
Lead 2.69 PPM
Copper 0.2 PPM
Nickel 0.61 PPM
Iron 5.81 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.