ITEM DETAILS
Meter Reading
2,610 Hours
Serial #
(4) Heaters, Stamford 21KW Generator, Kubota V2003-T Engine, 3,762 Liter Tank, (8) Hose Reels

The engine started and ran. The main components appear to be in place.

***Please See Seller Supplied Specifications Attached in the Documentation Section Below.***

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


Identification
Description Rating Details  
Serial Number / VIN V1C-556N6 Click here to open photos and videos of this item.  
(2)


Specifications
Description Rating Details  
Hour Meter /Odometer Reading 2610.7 Hours; Meter operational Click here to open photos and videos of this item.  
(1)


Additional Photos
Additional Photos #1 Click here to open photos and videos of this item.  
Additional Photos #2 Click here to open photos and videos of this item.  
(18)
 

Oil Sample Analysis
  engine
date of analysis Oct 17, 2018
Silicon 0 PPM
Tin 0 PPM
Silver 0.01 PPM
Aluminum 3.06 PPM
Chromium 0.8 PPM
Lead 0 PPM
Copper 26.52 PPM
Nickel 0.31 PPM
Iron 65.21 PPM
Glycol NEG
Water POS
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Related Equipment (Both Live and Sold)
Natural Gas Burner, Skid Mounted The item was ...
Natural Gas Burner, Skid Mounted The item was operational during a limited check.
Shop Built Heater Treater 6’ D X 20’H, ...
Shop Built Heater Treater 6’ D X 20’H, water leg, 24”D X 12’L separator, assorted plumbing, Kimray valves, assorted sized poly pipe, 3- Fire tubes. (NOTE: Buyer responsible for removal)
Cat C1.5 Diesel Engine, (2) ICE IDF-500HS 500,000 ...
Cat C1.5 Diesel Engine, (2) ICE IDF-500HS 500,000 BTU Heaters, S/A, Pintle Ring The engine started and ran. The main components appear to be in place and operational.**No title available. a bill of sale will be provided to transfer ownership ...
24”DIA x 10’L 4 Pass Coil 500,000 BTU ...
24”DIA x 10’L 4 Pass Coil 500,000 BTU Line Heater. Reconditioned in 2001