Previous Next
ITEM DETAILS
Meter Reading
2,902 Hours
Serial #

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
Summary Protected by IronClad Assurance Protected by IronClad Assurance®
This machine appears to be in good condition overall. The engine and hydraulic system seem to be in sound operating condition with minor leaks. The sheet metal is straight and the paint is good.


General Appearance
Description Rating Details  
sheet metal (fiberglass) condition Weld repairs on 1 fender. Click here to open photos and videos of this item.  
paint Chipped and scratched. Click here to open photos and videos of this item.  
(2)


Operator Station
Description Rating Details  
steps/ladders
hand rails
seats/armrests Click here to open photos and videos of this item.  
seat belts The retractor is inoperable.
exterior lights
warning lights/alarms
safety alarms INOPERABLE
oil pressure The warning light went out when the engine started.
gauges Click here to open photos and videos of this item.  
hour meter operational Yes
horn
hydraulic controls
steering controls Click here to open photos and videos of this item.  
powertrain controls
limited function check The components that were checked performed properly with wear and damage noted above.
(3)


Engine
Description Rating Details  
hour meter 2902
make & model Cummins 3.9 Click here to open photos and videos of this item.  
serial # 42727146
emission control label Yes
fuel type Diesel
starter Click here to open photos and videos of this item.  
battery
turbocharger Click here to open photos and videos of this item.  
exhaust system
cylinder head gasket
oil dipstick tube & bonnet Click here to open photos and videos of this item.  
blowby (checked at idle) Minor
valve cover gasket The retainer bolt gaskets are leaking oil. Click here to open photos and videos of this item.  
oil pan & gasket Click here to open photos and videos of this item.  
injector pump The hand pump is leaking oil. Click here to open photos and videos of this item.  
fuel line & injector leaks
water pump
radiator
limited function check Started easily and ran well with no unusual noises.
(7)


Powertrain
Description Rating Details  
transmission type Hydrostatic Click here to open photos and videos of this item.  
differential Shows oil seepage at the drain plug. Click here to open photos and videos of this item.  
final drives
limited function check The powertrain responded well with no unusual noises.
(2)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
articulating-center pins Minor noticeable play
steering linkage
steering wheel play Minimal
limited function check The main chassis components functioned properly with minor wear in the pivot points.
brake type Hydrostatic Dynamic
brake lines/ hoses
park brake
limited function check The brakes operated properly, stopping and holding the machine.
tire brand name Goodyear Click here to open photos and videos of this item.  
tire size 23.1x26
tire condition L/R 18/32", R/R 16/32". Click here to open photos and videos of this item.  
wheel condition
wheel studs, nuts or bolts
drum type Smooth
drum width 7'
drum condition
drum surface scraper or cleaner Click here to open photos and videos of this item.  
limited function check The chassis components functioned properly with wear as noted.
(3)


Hydraulics
Description Rating Details  
pumps
valves
hoses Click here to open photos and videos of this item.  
cylinders
cylinder pins and bushings Minor wear
drive motors Click here to open photos and videos of this item.  
vibrator motors Click here to open photos and videos of this item.  
limited function check The system functioned well with no unusual noises or visible leaks. See the oil sample analysis for the hydraulic system.
(3)


Additional Photos
(2)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Feb 04, 2003 Feb 04, 2003
analysis by Spectro Spectro
Tin 1 PPM 0 PPM
Chromium 0.3 PPM 0.2 PPM
Copper 1 PPM 79 PPM
Nickel 0.5 PPM 0.1 PPM
Lead 1 PPM 5 PPM
Magnesium 85 PPM 76 PPM
Water 0 % 0 %
Silver 0.1 PPM 0.1 PPM
Iron 16 PPM 6 PPM
Silicon 6 PPM 8 PPM
Sodium 3 PPM 7 PPM
Aluminum 2 PPM 1 PPM
Glycol N N
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.