Home Page / Vermeer RT100 Trencher
 

Vermeer RT100 Trencher (#451816)

Search for other Bore / Trench / Drill Equipment items   View all Sunbelt Rentals items

Winning Bid: US $1,200  
# of Bids: 4   View Bid History
Sold on: 5/30/13
Auction Type: Featured Event
SOLD!
Features: Walk Behind, 40" Trencher Bar, Discharge Auger, Honda GX-390 Engine
Meter Reading: Meter Broken
Serial Number:
Location: Alabama, United States
Zip/Postal Code:35405-3923
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Scratches; Chips
Sheet Metal (Fiberglass) Condition No visible damage; Surface rust
General Appearance #1
 
Control Station
Drivetrain Controls
Oil Pressure No oil pressure indicator
Hour Meter Inoperable hour meter; Hour meter difficult to read - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Limited Function Check The main components are in place and operational.
Control Station #1
 
Engine
Fuel Type Gasoline
Emission Control Label US EPA certification label
Fuel System Operational
Exhaust System Rust penetration
Oil Leaks None seen; High oil level
Fuel Leaks None seen
Limited Function Check (Engine) The engine started and ran.
Emission Control Label
 
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Transmission Type Hydrostatic
Drive Motors
Rear Drive Axle
Limited Function Check The drivetrain functioned without a load.
 
Hydraulics
Pumps (Hydraulics)
Hydraulic Motors
Valves
Hydraulic Tank
Hoses (Hydraulics)
Limited Function Check The hydraulic system was operational without a load.
Hydraulics #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Trenching Bar Scratched
Bar Pivot Point Minor to moderate movement
Holders and Cutting Bits Worn
Chain Roller Bushings
Discharge Auger Condition
Chain / Sprocket Condition Rusty; Dry; Worn sprockets
Bar Idler
Limited Function Check The main chassis components were operational in a limited check.
Holders and Cutting Bits Worn
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Frame Condition
Tire Size 18x9.50-8
Tire Condition See photos; Minor cuts and gouges
Wheel Condition
Wheel Studs, Nuts, Lugs
Chassis #1
Oil Sample Analysis Engine Hydraulic
date of analysis May 17, 2013 May 17, 2013
Silicon 7 PPM 4 PPM
Lead 0 PPM 0 PPM
Tin 1 PPM 13 PPM
Copper 1 PPM 5 PPM
Aluminum 3 PPM 3 PPM
Silver 0 PPM 0 PPM
Nickel 1.8 PPM 0.5 PPM
Chromium 0.3 PPM 0 PPM
Iron 21 PPM 3 PPM
Glycol NEG N/A
Water POS NEG
Fuel <5% N/A

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2014 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet®, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.