Features: Open Operator Station, Sun Canopy, Detroit Diesel 3 Cylinder Engine, 60" Padfoot Drum, Padfoot Shell Kit, 16.9-24 Tires
Meter Reading: Meter Broken
Serial Number:
Location: Virginia, United States
Zip/Postal Code:20187
(Fauquier County)
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Blemishes where decals have been removed; Scratches; Chips; Peeling; Bare spots; See photos for condition
Sheet Metal (Fiberglass) Condition Minor dents; Cracks; Surface rust; Metal corrosion; Minor corrosion
Steps/Ladders No visible damage
Hand Rails No visible damage
General Appearance #1
 
Control Station
Seats/Armrests Torn cover
Seat Belts Inoperable latch
Function Controls
Steering Control Minor to moderate steering wheel play
Drivetrain Controls
Oil Pressure No oil pressure indicator
Travel Alarm Inoperable
Gauges Inoperable
Hour Meter Not legible; Inoperable hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Limited Function Check The main components operated except as noted. The cab area is worn and weathered with surface rust in places.
Hour Meter
 
Engine
Fuel Type Diesel
Emission Control Label None found
Blow by @ idle (subjective observation) Minor
Starter Operational
Fuel System Operational
Exhaust System No visible damage
Radiator
Oil Leaks Fluid accumulation; Oil pan
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check (Engine) Required ether to start.
Engine #1
 
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Drive Motors
Final Drives
Drivetrain #1
 
Hydraulics
Pumps (Hydraulics) Not visually inspected
Valves Not visually inspected
Hydraulic Tank
Hoses Worn
Hydraulic Vibrator Motors
Steering Cylinders Heavy pin and bushing movement
Limited Function Check The hydraulic system was operational without a load.
Hydraulics #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Drum Condition
Padfoot / Chopper Feet Condition
Rubber Drum Isolators Cracks
Drum Scraper
Frame Condition
Articulating Center Pins Heavy movement
Park Brake Stopped the machine while rolling
Tire Condition Cuts; Gouges
Wheel Condition
Limited Function Check (roller) The components that were checked were operational with wear and damage.
Chassis #1

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2014 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet®, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.