Home Page / 2007 Komatsu PC2000-8 Track Excavator
 
Auction Closed on
9/29/14
Opened At
US $194,000
NOT SOLD
ITEM DETAILS
35,447 Hours
Enclosed Cab, A/C, Heater, Komatsu SAA12V140E-3 Engine, 155" Stick, 39 1/2" Track Shoes, 112" Tooth Bucket, Auto-Lube System. *** See link below for Seller Supplied Document of Accrued Hours Since Component Rebuild *** ***Item has been disassembled for transport by the seller post inspection. Buyer will be responsible for arranging crane service to load.***

Inspected by IronPlanet.

Your purchase is protected by our Ironclad Assurance.

IronPlanet Inspection Report



Please Note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
 
Videos


General Appearance
Description Rating Details  
CE Mark (on or near data plate) No
Paint Touch up paint; Scratches; Chips
Sheet Metal (Fiberglass) Condition Dents; Surface rust; Bent panels; Some newer panels are crated and stored; See photos
Steps/Ladders See photos for condition
Hand Rails Newer hand rails in crated and stored; See photos for condition
 (12)


Control Station
Description Rating Details  
Mirrors Some are removed from machine
Glass
Seats/Armrests
Seat Belts Operational
Horn Operational
Safety Lock Out/Stop
Hydraulic Controls Loose boots
Drivetrain Controls
Oil Pressure The fault indicator shuts off after the engine oil pressure rises
Exterior Lights Operational Yes; Some inoperable
Warning Lights Operational
Travel Alarm Operational
Gauges Operational
Hour Meter 35,447 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
  
Air Conditioner Ambient temperature too cold to check
  
Heater Operational
Limited Function Check The main components are in place and operational. There is a loose plastic cover on the left side beside seat in cab. Seller Comments: New plastic cover ordered
 (16)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Control Label US EPA certification label
  
Blow by @ idle (subjective observation) Minor
  
Starter Operational
Turbo or Blower No visible damage
Fuel System Operational
Exhaust System Leaks at connections
Radiator
Oil Leaks Fluid accumulation: Side of engine; Oil pan
Fuel Leaks None seen
Cooling System Leaks Fluid accumulation: Radiator hose; Fluid accumulation on and at base of engine area; See photos for condition
Limited Function Check (Engine) The engine started and ran. There is fluid accumulation at the base of the engine area. See oil report.
 (18)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Covers removed, Spare right side drive motor included and is stored in a crate
Final Drives
Limited Function Check The drivetrain functioned without a load. There is a spare right side drive motor included. It is stored in a crate.
 (4)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Fluid accumulation
Valves Fluid accumulation; Seepage
Hydraulic Tank
Hoses (Hydraulics)
Swing Motor Fluid accumulation
Hydraulic Center Swivel Fluid accumulation
Boom Lift Cylinder(s) Fluid accumulation on the left & right cylinder; Minor to moderate pin and bushing movement
Stick Cylinder Fluid accumulation; Minor to moderate pin and bushing movement
Bucket Cylinder Fluid accumulation; Chrome damage; Minor to moderate pin and bushing movement
Limited Function Check The hydraulic system was operational without a load. See oil report.
 (27)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Boom Condition Weld repair; Plated
Stick Condition Minor dents on inside of stick
Boom Base Pin and Bushings Moderate movement
Pin and Bushings Boom to Stick Moderate movement
Turn-Table Bearing Performs within tolerance expected for age and hours
Roller Frames Dented
Limited Function Check The main components were functional in a limited check.
 (15)


Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Track Pads See photos for condition
Track Tensioners See photos for condition
Grouser Height Left Side: 21 mm; Right Side: 21 mm
Track links See photos for condition
Pins and Bushings Turned? No
Pins and bushings See photos for condition
  
Carrier Rollers See photos for condition; (5) Show uneven wear; (4) New in storage
Track Rollers See photos for condition
Idlers See photos for condition
Sprockets See photos for condition
Limited Function Check There are (4) new carrier rollers included. They are stored in a crate.
 (24)


Specialty
Description Rating Details  
Excavator Bucket Condition
Backhoe / Excavator Bucket Shanks and Teeth
 (18)
 

Oil Sample Analysis
  Engine Hydraulic
date of analysis Apr 17, 2013 Apr 17, 2013
Silicon 0 PPM 7 PPM
Lead 0 PPM 2 PPM
Tin 1 PPM 0 PPM
Copper 0 PPM 32 PPM
Aluminum 0 PPM 3 PPM
Silver 0 PPM 0.1 PPM
Nickel 0.6 PPM 0.3 PPM
Chromium 0.2 PPM 2 PPM
Iron 1 PPM 16 PPM
Glycol NEG N/A
Water NEG NEG
Fuel <5% N/A

Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.