Features: Enclosed Cab, A/C, Heater, Cummins Engine, Long Reach Boom and Stick, 26' Stick, 31 1/2" Track Shoes, 61" Smooth Edge Bucket
Meter Reading: 8,291 Hours
Serial Number:
Location: Florida, United States
Zip/Postal Code:32571
(Pensacola area)
Shipping: Get a shipping estimate and see important pickup terms
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced. Free of visible wear or defects.
Performs within the tolerances expected for age and type of item.
Although performing, shows indication of needing repair or replacement.
Needs immediate repair/replacement. Requires work if it is to perform
as expected.
 
General Appearance
Paint Blemishes where decals have been removed; Scratches; Chips; See photos for condition
Sheet Metal (Fiberglass) Condition See photos for condition; Surface rust; Metal corrosion; Metal erosion
Steps/Ladders No visible damage
Hand Rails See photos for condition
General Appearance #1
 
Control Station
Glass The lower front plexiglass is scratched and cloudy
Seats/Armrests Damaged armrest; Torn Cover; See photos for condition
Seat Belts Inoperable latch; Inoperable retract
Horn Inoperable
Safety Lock Out/Stop
Hydraulic Controls
Drivetrain Controls Difficult to steer
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Exterior Lights Operational No
Warning Lights Operational; A warning light is flashing
Travel Alarm Inoperable
Gauges Operational
Hour Meter 8,291 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Air Conditioner Inoperable
Heater Inoperable
Limited Function Check The main components operated except as noted.
Hour Meter
 
Engine
Fuel Type Diesel
Emission Control Label None found
Blow by @ idle (subjective observation) Significant
Starter Operational
Turbo or Blower Significant rust
Fuel System Operational
Exhaust System No visible damage
Radiator Internal corrosion buildup; Significant rust in the radiator compartment; Seepage
Oil Leaks Dripping Leak: Front of engine. Seepage: Oil Pan.
Fuel Leaks None seen
Cooling System Leaks Seepage: Radiator.
Limited Function Check (Engine) After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting; The throttle is inoperable from the cab and has to be done manually at the engine
Blow by @ idle (subjective observation)
 
Drivetrain
Drive Motors Difficult to steer; Fluid Accumulation
Final Drives Fluid Accumulation
Limited Function Check The drivetrain was operational except as noted.
Drivetrain #1
 
Hydraulics
See photos for condition
Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses (Hydraulics) Worn; Fluid accumulation
Swing Motor The machine continues to swing after the control is released
Hydraulic Center Swivel
Boom Lift Cylinder(s) Fluid accumulation on the left cylinder; Fluid accumulation on the right cylinder; Moderate pin and bushing movement
Stick Cylinder Moderate pin and bushing movement
Bucket Cylinder Fluid accumulation; Moderate pin and bushing movement
Limited Function Check The hydraulic system was operational without a load.
Hydraulics #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Boom Condition
Stick Condition
Swing Tower Pivot Moderate movement
Boom Base Pin and Bushings Moderate movement
Pin and Bushings Boom to Stick Moderate movement
Pin and Bushings Stick to Bucket Moderate movement
Turn-Table Bearing Although Performing, shows indication of needing repair or replacement
Bottom Covers Missing covers
Roller Frames Rusty
Limited Function Check The main components were functional in a limited check.
Chassis #1
 
Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Track Pads See photos for condition; Bent pads
Track Tensioners See photos for condition
Grouser Height 15 mm
Track links See photos for condition
Pins and Bushings Turned? Yes
Pins and bushings See photos for condition
Carrier Rollers See photos for condition
Track Rollers See photos for condition
Idlers See photos for condition
Sprockets See photos for condition
Pins and bushings
 
Specialty
Excavator Bucket Condition
Specialty #1
Oil Sample Analysis Engine Hydraulic
date of analysis May 30, 2013 May 30, 2013
Silicon 6.72 PPM 7.63 PPM
Lead 3.02 PPM 4.76 PPM
Tin 0 PPM 0 PPM
Copper 0.38 PPM 11.69 PPM
Aluminum 2.55 PPM 1.17 PPM
Silver 0.07 PPM 0.05 PPM
Nickel 0.69 PPM 0.07 PPM
Chromium 0.98 PPM 0.57 PPM
Iron 57.22 PPM 3.23 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% N/A

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.