Home Page / Vermeer RTX1250 Cable Plow
 

Vermeer RTX1250 Cable Plow (#429651)

Search for other Bore / Trench / Drill Equipment items

Highest bid: US $35,000
Reserve not met
 
# of Bids: 1
Auction Closed on: 2/14/14
Auction Type: Daily Marketplace
RESERVE NOT MET
Features: Rear Steering, Reel Attachment, Cummins QSB4.5 Engine, 18" Rubber Tracks
Meter Reading: 539 Miles
Serial Number:
Location: Oklahoma, United States
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Scratches; See photos for condition
Sheet Metal (Fiberglass) Condition Cracked canopy; See photos for condition
Steps/Ladders No visible damage
Hand Rails No visible damage
General Appearance #1
 
Control Station
Seats/Armrests
Seat Belts Operational
Hydraulic Controls Some play observed
Steering Controls
Drivetrain Controls
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Warning Lights Operational
Gauges Operational
Hour Meter/Odometer 539 Hours; The unit was not operated long enough to verify the functionality of the hour meter. - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Interior
Limited Function Check The main components are in place and operational.
Hour Meter/Odometer
 
Engine
Limited Function Check (Engine) See oil report.
Fuel Type Diesel
Emission Control Label US EPA certification label
Blow by @ idle (subjective observation) Minimal
Starter Operational
Turbo or Blower No visible damage
Fuel System Operational
Exhaust System No visible damage
Radiator
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check (Engine) After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting. The ambient temperature was 25 degrees. The dust cover for air breather is missing.
Emission Control Label
 
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Drive Motors
Final Drives
Transmission Operational
Travel Speeds Variable single
Limited Function Check (Drivetrain-Track) The drivetrain was operational without a load. There is fluid accumulation at the rear seals.
Drivetrain #1
 
Hydraulics
Pumps (Hydraulics) Fluid accumulation
Hydraulic Motors Fluid accumulation
Valves
Hydraulic Tank
Hoses (Hydraulics) Fluid accumulation
Bar Lift Cylinders Minor to moderate pin and bushing movement
Plow Lift Cylinder Minor to moderate pin and bushing movement; Fluid accumulation
Chassis Leveling Cylinders Minor to moderate pin and bushing movement
Blade Cylinders Minor to moderate pin and bushing movement; Fluid accumulation
Limited Function Check The hydraulic system was operational without a load.
Hydraulics #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Backfill Blade
Frame Condition
Roller Frames
Belly pans
Limited Function Check (Chassis) The main components were operational when checked without a load.
 
Vibratory Plow
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Plow Shank Condition
Plow Vibrator
Reel Guide Sheave System Missing
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Steering Linkage
Brake Type Hydraulic
Brake Control
Park Brake
Limited Function Check The brake system functioned, stopping and holding the machine.
Chassis #1
 
Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Overall Machine Width (Outsides of tracks.) 96"
Grouser Height Measurement Front tracks: 16mm; Rear tracks: 22mm
Track Belt Condition See photos for condition
Rubber Belt Drive Lugs See photos for condition
Track Tensioners See photos for condition
Carrier Rollers See photos for condition
Track Rollers See photos for condition
Sprockets See photos for condition
Idlers See photos for condition
Undercarriage #1
Oil Sample Analysis Engine
date of analysis Jan 03, 2013
Silicon 5 PPM
Lead 1 PPM
Tin 0 PPM
Copper 2 PPM
Aluminum 2 PPM
Silver 0.1 PPM
Nickel 1.5 PPM
Chromium 0.6 PPM
Iron 15 PPM
Glycol NEG
Water NEG
Fuel <5%

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2014 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet®, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.