| Inspection Ratings Key |
 |
New or recently replaced |
 |
Performs within the tolerances expected for age and type of equipment |
 |
Although performing, shows indication of needing repair or replacement |
 |
Needs immediate repair/replacement. Requires work if it is to perform as expected |
|
|
| |
| General Appearance |
| Serial Number / VIN |
|
|
| CE Certification Label |
|
|
| Paint |
 |
|
| Sheet metal (fiberglass) condition |
 |
|
|
General Appearance #1
|
| |
| Control Station |
| Steps/Ladders |
 |
|
| Hand Rails |
 |
|
| Mirrors |
 |
|
| Glass |
 |
|
| Seats/Armrests |
 |
|
| Seat Belts |
 |
|
| Horn |
|
|
| Control Lock Lever |
 |
|
| Hydraulic Controls |
 |
|
| Steering Controls |
 |
|
| Powertrain Controls |
 |
|
| Oil Pressure |
|
|
| Exterior Lights Functional |
|
|
| Engine Warning Lights |
|
|
| Travel Alarm |
|
|
| Gauges |
|
|
| Hour Meter/Odometer |
|
- IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
|
| Air Conditioner |
|
|
| Heater |
|
|
| Limited Function Check (cs) |
|
|
|
Hour Meter/Odometer
|
| |
| Engine |
| Engine Make and Model |
|
|
| Fuel Type |
|
|
| Emission Control Label |
|
|
| Block Heater |
|
|
| Blow by @ idle (subjective observation) |
|
|
| Starter |
 |
|
| Turbo or Blower |
|
|
| Injector Pump |
|
|
| Exhaust System |
 |
|
| Radiator |
 |
|
| Head Gasket Leaks |
|
|
| Oil Leaks |
|
|
| Fuel Leaks |
|
|
| Cooling System Leaks |
|
|
| Limited Function Check |
|
|
|
Emission Control Label
|
| |
| Drivetrain |
| Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage. |
| Drive Motors |
 |
|
| Limited Function Check |
|
|
|
Drivetrain #1
|
| |
| Hydraulics |
| Pumps (Hydraulics) |
 |
|
| Valves |
 |
|
| Hydraulic Tank |
 |
|
| Hoses (Hydraulics) |
 |
|
| Auxiliary Hydraulic Plumbing |
|
|
| Cylinders |
 |
|
| Cylinder Pins and Bushings |
 |
|
| Limited Function Check |
|
|
|
Hydraulics #1
|
| |
| Chassis |
| IronPlanet turn-table bearing and pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed. |
| Roller Frames |
 |
|
| Belly pans |
 |
|
| Limited Function Check (loader) |
|
|
| Lift Arm Condition |
 |
|
| Chassis to Arm Pins |
 |
|
| Bucket to Arms Pins |
 |
|
| Quick Coupler to Arms Pins |
 |
|
| Limited Function Check (rt machines) |
|
|
|
Chassis #1
|
| |
| Undercarriage |
| Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail. |
| Overall Machine Width (Outsides of tracks.) |
|
|
| Grouser Height Measurement |
|
|
| Track Belt Width |
|
|
| Track Belt Condition |
|
|
| Rubber Belt Drive Lugs |
|
|
| Track Tensioners |
|
|
| Front Idler wear |
|
|
| Track Rollers |
|
|
| Sprockets |
|
|
| Limited Function Check (Undercarriage) |
|
|
|
Undercarriage #1
|
| |
| Specialty |
| Loader Bucket Condition |
|
|
| Loader Bucket Cutting Edge |
 |
|
| Quick Coupler |
 |
|
|
Specialty #1
|
| Oil Sample Analysis |
Engine |
Hydraulic |
| date of analysis |
Nov 02, 2009 |
Nov 02, 2009 |
| Silicon |
2 PPM |
4 PPM |
| Lead |
0 PPM |
4 PPM |
| Tin |
0 PPM |
0 PPM |
| Copper |
1 PPM |
18 PPM |
| Aluminum |
0 PPM |
1 PPM |
| Silver |
0.1 PPM |
0.8 PPM |
| Nickel |
0.2 PPM |
0.3 PPM |
| Chromium |
0.1 PPM |
0.1 PPM |
| Iron |
3 PPM |
7 PPM |
| Glycol |
NEG |
N/A |
| Water |
NEG |
NEG |
| Fuel |
<5% |
N/A |
|