Minor dents/ scrapes; Radiator guard screen is dented and damaged.
Serial Number / VIN
Control Station
Hydraulic Controls
Backhoe Control Configuration
4 Lever (FORD) type w/foot swing
Steps/Ladders
Left Side: Bent
Hand Rails
Mirrors
Missing
Glass
Glass guards are found on each side of the dash/operator's console.
Seats/Armrests
Dirty; Armrest's surfaces are damaged
Seat Belts
Horn
Functional
Powertrain Controls
Steering Controls
Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Exterior Lights Functional
Yes
Engine Warning Lights
Functional
Travel Alarm
Functional
Gauges
Functional
Hour Meter/Odometer
Functional; 5298.6; Hours
- IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Limited Function Check (cs)
The main components functioned during a limited check.
Hour Meter/Odometer
Engine
Engine Make and Model
Cat 3054 engine; S/N: 7BJ67411
Fuel Type
Diesel
Emission Control Label
US EPA certification label
Blow by @ idle (subjective observation)
Minimal
Starter
Turbo or Blower
Operational
Injector Pump
Operational
Exhaust System
Radiator
Head Gasket Leaks
None seen
Oil Leaks
None seen
Fuel Leaks
None seen
Cooling System Leaks
None seen
Limited Function Check
The engine started and ran during a limited check. See oil report.
Emission Control Label
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Transmission
Floor shift w/shuttle lever
Torque Converter
Functional
Differential (front)
Differential (rear)
Final Drives
Limited Function Check
The drivetrain functioned during a limited check without a load. See oil report.
Drivetrain #1
Hydraulics
Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses (Hydraulics)
Some fittings have rust and/or corrosion.
Cylinders
Scratches in chrome on stabilizer cylinder rods.
Cylinder Pins and Bushings
Wear consistent with hours and age
Limited Function Check
The hydraulic system was operational during a limited check without a load.
Hydraulics #1
Chassis
IronPlanet turn-table bearing and pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Steering Linkage
Wear consistent with hours and age
Steering Wheel Play
Minimal
Brake Type
Hydraulic
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake
Held on slope
Limited Function Check (Brakes)
The brake system functioned, stopping and holding the machine.
Frame Condition
Tire Size (4)
12.5/80-18 front tires; 19.5R-24 rear tires; Fronts: SOLIDEAL; Rears: DEESTONE
Tire Condition
Cuts
Tread Depth (4 tires)
RF 11 mm; LF 9 mm; RR 6 mm; LR 4 mm
Wheel Condition
Wheel Studs, Nuts, Lugs
Lift Arm Condition
Chassis to Arm Pins
Wear consistent with hours and age
Tilt Linkage Pins and Bushings
Wear consistent with hours and age
Bucket to Arms Pins
Wear consistent with hours and age
Limited Function Check (rt machines)
The main chassis components functioned during a limited check.
Boom Condition
Scraped; Dented
Stick Condition
Scraped; Outer housing has heavy dents but functions.
Stick Type
Extendable stick; Functional
Extendahoe Stick Guide
Minor wear
Boom Lock (Backhoe)
Boom Base Pin and Bushings
Wear consistent with hours and age
Pin and Bushings Boom to Stick
Wear consistent with hours and age
Pin and Bushings Stick to Bucket
Wear consistent with hours and age
Outriggers
Street pads
Stabilizer Cylinders
Scratches in chrome on cylinder rods
Limited Function Check (Backhoe)
The main components were functional with minimal wear.
Chassis #1
Specialty
Backhoe / Excavator Bucket Condition
18" Width
Backhoe / Excavator Bucket Cutting Edge
Teeth have unequal wear and are mismatched.
Loader Bucket Cutting Edge
Reversible-turned
Loader Bucket Condition
88" Multi-purpose loader bucket; Weld repaired
Specialty #1
Oil Sample Analysis
Engine
Transmission
date of analysis
Oct 26, 2009
Oct 26, 2009
Silicon
6 PPM
2 PPM
Lead
1 PPM
2 PPM
Tin
2 PPM
0 PPM
Copper
7 PPM
8 PPM
Aluminum
5 PPM
0 PPM
Silver
0 PPM
0 PPM
Nickel
0.3 PPM
0.3 PPM
Chromium
0.4 PPM
0 PPM
Iron
10 PPM
21 PPM
Glycol
NEG
N/A
Water
NEG
NEG
Fuel
<5%
N/A
Note: This condition inspection report is the result of an impartial, systematic, documented process focused on the establishment of the general, overall mechanical condition of a piece of equipment, or of a vehicle, at a specific time. The purpose of the inspection is to establish the "as-is" operational capability of the machine. It is not a performance or load test on the equipment.
Pickup Terms Failure to follow these terms may result in the seller turning away the attempt of your driver to pick up the purchased item.
Buyer will be responsible for any transportation charges issued by the driver.
Location: California, United States
Zip/Postal Code: 92056
(San Diego area)
The purchase of this item is subject to California sales tax unless certain conditions are met.
Hours: 8am to 5pm Mon-Fri
Call at least one day in advance to schedule pickup.
NO LOADING DOCK AVAILABLE: Only RGN and trailers with ramps can be used for pickup.
Driver MUST bring a copy of the IronPlanet Transportation Release to pick the item up.