| Inspection Ratings Key |
 |
New or recently replaced |
 |
Performs within the tolerances expected for age and type of equipment |
 |
Although performing, shows indication of needing repair or replacement |
 |
Needs immediate repair/replacement. Requires work if it is to perform as expected |
|
|
| |
| General Appearance |
| Serial Number / VIN |
|
|
| CE Certification Label |
|
|
| Paint |
 |
|
| Sheet metal (fiberglass) condition |
 |
|
|
Serial Number / VIN
|
| |
| Control Station |
| Steps/Ladders |
 |
|
| Hand Rails |
 |
|
| Mirrors |
 |
|
| Glass |
 |
|
| Seats/Armrests |
 |
|
| Seat Belts |
 |
|
| Horn |
|
|
| Control Lock Lever |
 |
|
| Disconnect Control |
 |
|
| Hydraulic Controls |
 |
|
| Steering Controls |
 |
|
| Powertrain Controls |
 |
|
| Oil Pressure |
|
|
| Exterior Lights Functional |
|
|
| Engine Warning Lights |
|
|
| Travel Alarm |
|
|
| Gauges |
|
|
| Hour Meter/Odometer |
|
- IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
|
| Limited Function Check (cs) |
|
|
|
Hour Meter/Odometer
|
| |
| Engine |
| Engine Make and Model |
|
|
| Fuel Type |
|
|
| Emission Control Label |
|
|
| Blow by @ idle (subjective observation) |
|
|
| Starter |
 |
|
| Turbo or Blower |
|
|
| Injector Pump |
|
|
| Exhaust System |
 |
|
| Radiator |
 |
|
| Head Gasket Leaks |
|
|
| Oil Leaks |
|
|
| Fuel Leaks |
|
|
| Cooling System Leaks |
|
|
| Limited Function Check |
|
|
|
Emission Control Label
|
| |
| Drivetrain |
| Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage. |
| Drive Motors |
 |
|
| Limited Function Check |
|
|
|
|
| |
| Hydraulics |
| Pumps (Hydraulics) |
 |
|
| Hydraulic Motors |
 |
|
| Valves |
 |
|
| Hydraulic Tank |
 |
|
| Hoses (Hydraulics) |
 |
|
| Auxiliary Hydraulic Plumbing |
|
|
| Cylinders |
 |
|
| Cylinder Pins and Bushings |
 |
|
| Limited Function Check |
|
|
|
Hydraulics #1
|
| |
| Chassis |
| IronPlanet turn-table bearing and pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed. |
| Roller Frames |
 |
|
| Belly pans |
 |
|
| Lift Arm Condition |
 |
|
| Chassis to Arm Pins |
 |
|
| Quick Coupler to Arms Pins |
 |
|
| Limited Function Check (rt machines) |
|
|
|
Chassis #1
|
| |
| Undercarriage |
| Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail. |
| Overall Machine Width (Outsides of tracks.) |
|
|
| Grouser Height Measurement |
|
|
| Track Belt Width |
|
|
| Track Belt Condition |
|
|
| Rubber Belt Drive Lugs |
|
|
| Track Tensioners |
|
|
| Front Idler wear |
|
|
| Rear idler wear |
|
|
| Track Rollers |
|
|
| Sprockets |
|
|
| Limited Function Check (Undercarriage) |
|
|
|
Undercarriage #1
|
| |
| Specialty |
| Quick Coupler |
 |
|
|
Specialty #1
|
| Oil Sample Analysis |
Engine |
Hydraulic |
| date of analysis |
Oct 19, 2009 |
Oct 19, 2009 |
| Silicon |
11 PPM |
10 PPM |
| Lead |
2 PPM |
3 PPM |
| Tin |
3 PPM |
0 PPM |
| Copper |
12 PPM |
15 PPM |
| Aluminum |
6 PPM |
1 PPM |
| Silver |
0 PPM |
0.4 PPM |
| Nickel |
0.5 PPM |
0.1 PPM |
| Chromium |
1.1 PPM |
0.5 PPM |
| Iron |
45 PPM |
14 PPM |
| Glycol |
NEG |
N/A |
| Water |
NEG |
NEG |
| Fuel |
<5% |
N/A |
|
Note: This condition inspection report is the result of an impartial, systematic, documented process focused on the establishment of the general, overall mechanical condition of a piece of equipment, or of a vehicle, at a specific time. The purpose of the inspection is to establish the "as-is" operational capability of the machine. It is not a performance or load test on the equipment. |
Pickup Terms
Failure to follow these terms may result in the seller turning away the attempt of your driver to pick up the purchased item.
Buyer will be responsible for any transportation charges issued by the driver.
- Location: Florida, United States
-
Zip/Postal Code: 32234
(Jacksonville area)
- The purchase of this item is subject to Florida sales tax unless certain conditions are met.
- Hours: M-F 9:00 AM - 4:00 PM
- Call at least one day in advance to schedule pickup.
- NO LOADING DOCK AVAILABLE: Only RGN and trailers with ramps can be used for pickup.
- Driver MUST bring a copy of the IronPlanet Transportation Release to pick the item up.
- Call 24 hours in advance of pick-up
| We Suggest You Also See... |
|