There are dents and scrapes on the sheet metal. There is rust penetration in the sheet metal. The fiberglass hood is cracked. The bumper protectors for the radiator are damaged.
Serial Number / VIN
Control Station
Hydraulic Controls
Backhoe Control Configuration
Excavator style w/control pattern changer
Steps/Ladders
Hand Rails
Mirrors
Glass
Seats/Armrests
Damaged base boot
Seat Belts
Horn
Functional
Powertrain Controls
Steering Controls
Oil Pressure
The fault indicator shuts off after the engine oil pressure rises.
Exterior Lights Functional
Yes; Some Inoperable
Engine Warning Lights
Functional
Travel Alarm
Functional
Gauges
Functional
Hour Meter/Odometer
Functional 1,834 Hours
- IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Air Conditioner
Functional
Heater
Functional
Disconnect Control
Limited Function Check (cs)
The components that were checked functioned except as noted.
Hour Meter/Odometer
Engine
Engine Make and Model
Cat 3054 engine Serial #: 7BJ27010
Fuel Type
Diesel
Emission Control Label
US EPA certification label
Blow by @ idle (subjective observation)
Minimal
Starter
Turbo or Blower
Operational
Injector Pump
Operational
Exhaust System
The muffler leaks around the clamp.
Radiator
Dirty
Head Gasket Leaks
None seen
Oil Leaks
None seen
Fuel Leaks
None seen
Cooling System Leaks
None seen
Limited Function Check
The engine started and ran during a limited check. See oil report.
Emission Control Label
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Transmission
4 speed floor shift w/shuttle lever
Torque Converter
Feels normal
Differential (front)
Differential (rear)
Differential lock; Residue on housing
Final Drives
Limited Function Check
The drivetrain functioned during a limited check without a load. See oil report.
Drivetrain #1
Hydraulics
Pumps (Hydraulics)
Hydraulic Motors
Valves
Hydraulic Tank
Sight glass is cloudy.
Hoses (Hydraulics)
Steel braid exposed and broken clamps
Cylinders
Cylinder Pins and Bushings
Wear consistent with hours and age
Limited Function Check
The hydraulic system was operational during a limited check without a load.
Hydraulics #1
Chassis
IronPlanet turn-table bearing and pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Steering Linkage
Wear consistent with hours and age
Steering Wheel Play
Minor
Brake Type
Hydraulic
Master Cylinder/Brake Control
Brake Lines/Hoses
Park Brake
Held against power
Limited Function Check (Brakes)
The brake system functioned, stopping and holding the machine.
Frame Condition
Tire Size (4)
12.5/ 80- 18 front tires; 19.5 L-24 rear tires;
Brands Armour and Goodyear
Tire Condition
Cuts and gouges
Tread Depth (4 tires)
RF 24 mm; LF 21 mm; RR 6 mm; LR 8 mm
Wheel Condition
Wheel Studs, Nuts, Lugs
Lift Arm Condition
Chassis to Arm Pins
Wear consistent with hours and age
Tilt Linkage Pins and Bushings
Wear consistent with hours and age
Bucket to Arms Pins
Wear consistent with hours and age
Limited Function Check (rt machines)
The main chassis components functioned during a limited check.
Boom Condition
Scratched
Stick Condition
Scratched
Stick Type
Extendable stick
Extendahoe Stick Guide
Minor wear; Dry
Boom Lock (Backhoe)
Boom Base Pin and Bushings
Wear consistent with hours and age
Pin and Bushings Boom to Stick
Wear consistent with hours and age
Pin and Bushings Stick to Bucket
Wear consistent with hours and age
Outriggers
Street pads; Dirt pads; The street pads are worn.
Stabilizer Cylinders
Limited Function Check (Backhoe)
The main components were functional with minimal wear.
Chassis #1
Specialty
Backhoe / Excavator Bucket Condition
24" Rear bucket
Backhoe / Excavator Bucket Cutting Edge
Teeth worn
Loader Bucket Cutting Edge
Reversible-turned; Worn/damaged edge
Loader Bucket Condition
88" General purpose bucket; Dented
Specialty #1
Oil Sample Analysis
Engine
Transmission
date of analysis
Nov 03, 2009
Nov 03, 2009
Silicon
5 PPM
7 PPM
Lead
1 PPM
0 PPM
Tin
1 PPM
0 PPM
Copper
32 PPM
11 PPM
Aluminum
5 PPM
2 PPM
Silver
0.1 PPM
0 PPM
Nickel
0.9 PPM
0 PPM
Chromium
1.1 PPM
0.2 PPM
Iron
57 PPM
38 PPM
Glycol
NEG
N/A
Water
NEG
NEG
Fuel
<5%
N/A
Note: This condition inspection report is the result of an impartial, systematic, documented process focused on the establishment of the general, overall mechanical condition of a piece of equipment, or of a vehicle, at a specific time. The purpose of the inspection is to establish the "as-is" operational capability of the machine. It is not a performance or load test on the equipment.
Pickup Terms Failure to follow these terms may result in the seller turning away the attempt of your driver to pick up the purchased item.
Buyer will be responsible for any transportation charges issued by the driver.
Location: Arizona, United States
Zip/Postal Code: 85231
(Phoenix-Mesa area)
The purchase of this item is subject to Arizona sales tax unless certain conditions are met.
Hours: LOADING HOURS: 8:30 am - 3:30 pm; Mon-Fri
Call at least one day in advance to schedule pickup.
Loading Dock Available.
Driver MUST bring a copy of the IronPlanet Transportation Release to pick the item up.