| Features: |
Open dual operator station, Cummins QSB 5.9-30TAA engine, hydrostatic drive, 120" screed extendable to 240", 19" track belts ~This item subject to storage fees of $100 per day if not removed after 30 business days following the close of auction. Item must be removed before end of 60 days after close of auction to avoid abandonment. |
|
|
|
Meter Reading:
|
7,255 Hours
|
|
Serial Number:
|
551030-24
|
| Location: |
Maine, United States
Zip/Postal Code: 04092
(Portland area)
|
|
| |
Request shipping quote or additional assistance with transportation
More
Shipping Details
|
|
|
picture, brochure
|
| Inspection Ratings Key |
 |
New or recently replaced |
 |
Performs within the tolerances expected for age and type of equipment |
 |
Although performing, shows indication of needing repair or replacement |
 |
Needs immediate repair/replacement. Requires work if it is to perform as expected |
|
|
| |
| General Appearance |
| Serial Number / VIN |
|
|
| CE Certification Label |
|
|
| Paint |
 |
|
| Sheet metal (fiberglass) condition |
 |
|
|
Serial Number / VIN
|
| |
| Control Station |
| Steps/Ladders |
 |
|
| Hand Rails |
 |
|
| Mirrors |
 |
|
| Seats/Armrests |
 |
|
| Horn |
|
|
| Disconnect Control |
 |
|
| Hydraulic Controls |
 |
|
| Steering Controls |
 |
|
| Powertrain Controls |
 |
|
| Oil Pressure |
|
|
| Gauges |
|
|
| Hour Meter/Odometer |
|
- IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
|
| Limited Function Check (cs) |
|
|
|
Hour Meter/Odometer
|
| |
| Engine |
| Engine Make and Model |
|
|
| Fuel Type |
|
|
| Emission Control Label |
|
|
| Blow by @ idle (subjective observation) |
|
|
| Starter |
 |
|
| Turbo or Blower |
|
|
| Injector Pump |
|
|
| Exhaust System |
 |
|
| Radiator |
 |
|
| Head Gasket Leaks |
|
|
| Oil Leaks |
|
|
| Fuel Leaks |
|
|
| Cooling System Leaks |
|
|
| Limited Function Check |
|
|
|
Emission Control Label
|
| |
| Drivetrain |
| Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage. |
| Travel Speeds |
|
|
| Final Drives |
 |
|
| Limited Function Check (Drivetrain-Track) |
|
|
|
Drivetrain #1
|
| |
| Hydraulics |
| Pumps (Hydraulics) |
 |
|
| Hydraulic Motors |
 |
|
| Valves |
 |
|
| Hydraulic Tank |
 |
|
| Hoses (Hydraulics) |
 |
|
| Cylinders |
 |
|
| Cylinder Pins and Bushings |
 |
|
| Limited Function Check |
|
|
|
Hydraulics #1
|
| |
| Chassis |
| IronPlanet turn-table bearing and pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed. |
| Dimensions |
|
|
| Screed Model No |
|
|
| Screed Control Switches |
 |
|
| Screed Lift Arms |
 |
|
| Screed Bottom Plate / Mat |
 |
|
| Metering Gates |
 |
|
| Auger/ Screw Condition |
 |
|
| Feed Conveyors |
 |
|
| Conveyor Drive Chains and Sprockets |
 |
|
| Push Rollers |
 |
|
| Hopper Wings |
 |
|
| Screed Heaters |
 |
|
| Screed Slope Adjusters |
 |
|
| Screed Angle of Attack Adjusters |
 |
|
| Screed Power Extend |
 |
|
| Screed Wear Plates |
 |
|
| Extension Tubes |
 |
|
| End Gates |
 |
|
|
Chassis #1
|
| |
| Undercarriage |
| Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail. |
| Overall Machine Width (Outsides of tracks.) |
|
|
| Grouser Height Measurement |
|
|
| Track Belt Width |
|
|
| Track Belt Condition |
|
|
| Rubber Belt Drive Lugs |
|
|
| Track Tensioners |
|
|
| Front Idler wear |
|
|
| Track Rollers |
|
|
| Sprockets |
|
|
|
Undercarriage #1
|
| Oil Sample Analysis |
Engine |
Hydraulic |
| date of analysis |
Oct 21, 2009 |
Oct 21, 2009 |
| Silicon |
5 PPM |
6 PPM |
| Lead |
0 PPM |
1 PPM |
| Tin |
0 PPM |
0 PPM |
| Copper |
1 PPM |
240 PPM |
| Aluminum |
2 PPM |
1 PPM |
| Silver |
0 PPM |
1.1 PPM |
| Nickel |
0.2 PPM |
0.3 PPM |
| Chromium |
1.5 PPM |
0.1 PPM |
| Iron |
14 PPM |
13 PPM |
| Glycol |
NEG |
N/A |
| Water |
NEG |
NEG |
| Fuel |
<5% |
N/A |
|
Note: This condition inspection report is the result of an impartial, systematic, documented process focused on the establishment of the general, overall mechanical condition of a piece of equipment, or of a vehicle, at a specific time. The purpose of the inspection is to establish the "as-is" operational capability of the machine. It is not a performance or load test on the equipment. |
Pickup Terms
Failure to follow these terms may result in the seller turning away the attempt of your driver to pick up the purchased item.
Buyer will be responsible for any transportation charges issued by the driver.
- Location: Maine, United States
-
Zip/Postal Code: 04092
(Portland area)
- The purchase of this item is subject to Maine sales tax unless certain conditions are met.
- Hours: 8 - 4 Mon - Fri
- Call at least one day in advance to schedule pickup.
- NO LOADING DOCK AVAILABLE: Only RGN and trailers with ramps can be used for pickup.
- Driver MUST bring a copy of the IronPlanet Transportation Release to pick the item up.