ITEM DETAILS
8,640 Hours
Enclosed Cab, Heater, Caterpillar 3126 Engine, 24" Track Shoes, Prentice PD57 Harvester Head. Seller States: The harvester head on this machine is a 2010 PD Serial number: 10030 and the Forwarder is a 2003 Caterpillar TK711 and the Serial Number: TKA00203

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

IronPlanet Inspection Report



Please Note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark (on or near data plate) No
Paint Scrapes; Chips; See photos for condition
Sheet Metal (Fiberglass) Condition Minor dents; Surface rust; See photos for condition
Steps/Ladders Bent; See photos for condition
Hand Rails See photos for condition
 (17)


Control Station
Description Rating Details  
Glass Plexiglass; Broken front glass
Seats/Armrests
Seat Belts Operational
Horn Operational
Safety Lock Out/Stop
Hydraulic Controls
Drivetrain Controls
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Exterior Lights Operational Some inoperable; Some damaged
Warning Lights Operational
Hour Meter 8,640 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
  
Heater Fan inoperable
Limited Function Check The main components operated except as noted.
 (24)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Control Label Both EPA and EC certification
  
Blow by @ idle (subjective observation) Minor
  
Starter Operational
Turbo or Blower Exhaust connection leak
Fuel System Operational; Leak
Exhaust System Rust penetration
Radiator Significant plugging of fins; Cooler is wet with oil
Oil Leaks Dripping Leak: Rear of engine.
Fuel Leaks No dripping leaks seen
Cooling System Leaks None seen
Limited Function Check (Engine) The engine was running upon inspector arrival.
 (17)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors
Final Drives
Limited Function Check The drivetrain functioned without a load.
 (2)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Dripping leak
Valves Dripping leak
Hydraulic Tank
Hoses (Hydraulics) Leaks; Braid exposure; Seepage; Worn
Swing Motor Seepage
Hydraulic Center Swivel
Boom Lift Cylinder(s)
Stick Cylinder
Limited Function Check The hydraulic system was operational except as noted.
 (8)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Boom Condition
Stick Condition
Boom Base Pin and Bushings
Pin and Bushings Boom to Stick
Turn-Table Bearing Side to side movement
Bottom Covers
Roller Frames
Limited Function Check The main components were operational with damage as noted.
 (9)


Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Track Pads
Track Tensioners
Grouser Height 76 mm
Track links
Pins and Bushings Turned? No
Pins and bushings
  
Carrier Rollers
Track Rollers Full rock guards. Not visible.
Idlers
Sprockets
 (15)


Specialty
Description Rating Details  
Attachment (Other) Prentice PD57 Harvester; Operational
 (8)
 

Oil Sample Analysis
  engine
date of analysis Nov 13, 2013
Lead 0 PPM
Chromium 0.2 PPM
Copper 0.41 PPM
Silver 0 PPM
Nickel 0.52 PPM
Tin 0.11 PPM
Aluminum 1.69 PPM
Silicon 10.01 PPM
Iron 5.43 PPM
Glycol NEG
Water NEG
Fuel <5%

Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!