Back to Search Results / 1999 Gradall 534B-8 Telehandler
 

1999 Gradall 534B-8 Telehandler (#384600)

Search for other Telehandlers items

Winning Bid: US $8,000  
# of Bids: 2   View Bid History
Sold on: : 6/15/12
Auction Type: Featured Auction
SOLD!
Features: 8,000 lb Max. Weight Capacity, 36' Max. Lift Height, 46" Forks, Frame Leveling, Diesel, Open Operator Station. 13.00-24 Tires
Meter Reading: 2,101 Hours
Serial Number:
Location: Texas, United States
Zip/Postal Code:75482
(Hopkins County)
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Scratches; chips; see photos for condition
Sheet Metal (fiberglass) Condition Minor dents; scrapes; surface rust in areas; battery cover is off; see photos for condition
Hand Rails See photos for condition
General Appearance #1
 
Control Station
Glass Right side plexiglass; see photos for condition;
Seats/Armrests Inoperable slide or adjustment; see photos for condition
Seat Belts Operational
Horn Inoperable
Hydraulic Controls Loose
Steering Control
Drivetrain Controls Stiff
Oil Pressure The gauge registers in the operating range.
Gauges Operational; some gauges inoperable; torque temp/amps gauges inoperable
Hour Meter/Odometer 2,101 Hours; Operational Hour Meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Limited Function Check (cs) The main components operated except as noted.
Hour Meter/Odometer
 
Engine
Make and Model 4 Cylinder Engine
Fuel Type Diesel
Emission Control Label None found
Blow by @ idle (subjective observation) Visible; drips oil out of blow by tube
Starter Operational
Turbo or Blower Operational; exhaust connection leak; the connection to the exhaust pipe is disconnected/loose; missing hardware; see photos
Fuel System Operational
Exhaust System Broken; rust penetration; leaks; outlet pipe almost bent closed; disconnected; see photos for condition
Radiator
Oil Leaks Fluid accumulation: side of engine; oil pan; see photos
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check (Engine) After jump starting the engine ran with smoke that mostly cleared. See oil report.
Blow by @ idle (subjective observation)
 
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Transmission Operational; unusual noise. Note: 1st gear is operationally intermittent in forward & has no reverse or neutral; the unit tries to go both forward and reverse when in reverse in 1st gear
Drive Motors Noisy
Front Drive Axle Fluid accumulation; seepage; see photos
Final Drives Fluid accumulation; seepage; see photos
Limited Function Check The drivetrain was operational except as noted.
Drivetrain #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Lift Height 8,000 lb max. lift capacity; 36' max. lift height
Boom Condition Dry; jerks on return
Chain / Tensioners Moderate wear
Rollers and Guides
Boom Wear Guides Dry and worn
Load Back Rest Bent
Forks 46" forks; hole in tip; bent slide rod; carriage slightly bent
Frame Leveling Yes
Steering Linkage Heavy movement
Steering Wheel Play Minor to moderate movement
Frame Condition Surface rust
Limited Function Check The main chassis components functioned with wear in the pivot points.
Brake Type Hydraulic
Master Cylinder
Brake Control Difficult to operate
Brake Lines/Hoses Cracked/chafed
Park Brake Inoperable; seized lever
Limited Function Check Service brakes are weak.
Tire Size 13.00-24 tires; North Coast; Dynastar; Fidelity
Tire Condition Cuts; gouges; see photos
Wheel Condition Rusty
Wheel Studs, Nuts, Lugs
Chassis #1
 
Hydraulics
Pumps (Hydraulics) Noisy
Valves Seepage
Hydraulic Tank
Hoses (Hydraulics) Hoses on machine: loose; worn; braid exposure
Boom Lift Cylinder(s) Minor to moderate pin and bushing movement
Telescope Boom Cylinders
Fork Tilt Cylinders Minor to moderate pin and bushing movement
Side Shift Cylinder .
Fork Positioning Cylinder (on fork carriage) .
Steering Cylinders Fluid accumulation on the right cylinder; rust pitting in the chrome on the left & right cylinders
Limited Function Check The hydraulic system was operational without a load. See oil report.
Hydraulics #1
Oil Sample Analysis Engine Hydraulic
date of analysis May 10, 2012 May 10, 2012
Silicon 13 PPM 0 PPM
Lead 1 PPM 2 PPM
Tin 0 PPM 0 PPM
Copper 3 PPM 5 PPM
Aluminum 1 PPM 0 PPM
Silver 0 PPM 0 PPM
Nickel 0.1 PPM 0.1 PPM
Chromium 0.5 PPM 0.1 PPM
Iron 11 PPM 1 PPM
Glycol NEG N/A
Water NEG NEG
Fuel >5% N/A

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2013 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet℠, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.