Previous Next
Sold on
2/7/13
Winning Bid
US $35,000
Won using Buy Now Price
# of Bids
1
SOLD!
ITEM DETAILS
Meter Reading
Meter Broken
Serial #
40 Ton Capacity, 80' Maximum Boom Length, 33' Maximum Jib Length, Heater, Anti-Two-Block, Diesel Engine, Automatic Transmission, Ball Hook, Stabilizers. ***The state of Ohio does not require a title for this item. A Bill of Sale will be provided if requested.. Please check with your local agency for titling/export requirements***

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Safety Certification Label There is a safety certification label with a date of 2/20/04
Safety Certification Report None available at time of inspection.
Load Chart Yes
CE Mark No
Paint Blemishes where decals have been removed; Scratches; Chips; See photos for condition
Sheet Metal (fiberglass) Condition Minor dents; See photos for condition
Steps/Ladders See photos for condition
Hand Rails See photos for condition
(16)


Control Station
Description Rating Details  
Seat Belts Operational
Mirrors
Glass No visible damage
Seats/Armrests
Horn Operational
Anti Two Block Operational
Hydraulic Controls
Drivetrain Controls
Oil Pressure The gauge registers in the operating range; 50 PSI
Exterior Lights Yes; Some inoperable
Gauges Operational
Hoist Brakes Hydraulic
Hour Meter/Odometer (Start) 2410.0 Hours
Hour Meter/Odometer 2,410 Hours; Inoperable hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Indication of Additional Hours No other hrs were found on unit.
Heater Inoperable
Limited Function Check The main components operated except as noted.
(24)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Certification Label None found
Blow by @ idle (subjective visual observation) Visible Click here to open photos and videos of this item.  
Starter Operational
Fuel System Operational
Exhaust System Leaks; See photos for condition
Radiator
Oil Leaks Fluid accumulation; Valve cover; Side of engine; Oil pan
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check (Engine) The engine started and ran with smoke. The belts make noise when the engine is idled high but the noise quits after some running time. See oil report.
(6)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational
Front Drive Axle
Rear Drive Axle Fluid accumulation at universal
Final Drives
Limited Function Check The drivetrain was operational. See oil report.
(3)


Hydraulics
Description Rating Details  
Pumps (Hydraulics) Fluid accumulation
Hydraulic Motors
Valves Fluid accumulation
Hydraulic Tank
Hoses (Hydraulic) Hydraulic motor hoses; Worn; Hoses on machine; Seepage
Swing Motor Fluid accumulation
Main Hoist
Auxiliary Hoist
Lift Cylinders Seepage; Minor to moderate pin and bushing movement
Telescopic Boom Cylinders (3) Sections extend by hydraulics; Fourth section is a dead section; Pins must be pulled and pushed out with another section
Cylinder Pins and Bushings Minor to moderate movement
Limited Function Check The hydraulic system was operational without a load. See oil report.
(21)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Steering Linkage Minor to moderate movement
Outrigger Cylinders
Steering Wheel Play Minor to moderate movement
Brake Type Air
Master Cylinder/Brake Control No visual on compressor
Park Brake Held against power; Stopped the machine while rolling
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Turntable Bearing Performs within tolerance expected for age and hours
Frame Condition
Tire Size 26.5-25 Tires; All same brand; General
Tire Condition Air filled; See photos
Tread Depth (4 tires) LF 16 mm; LR 11 mm; RR 11 mm; RF 16 mm
Wheel Condition
Wheel Studs
Limited Function Check The main chassis components were operational in a limited check.
Outrigger Condition
Outrigger Beams
Outrigger Floats/Pads Condition Bent
Main Boom Pins Minimal movement
Main Boom Sections
Sheaves
Boom Head Section
Boom Extension Condition Fourth section was not extended at time of inspection; Fourth section is considered a dead section (per seller)
Extension Chains / Cables Not visible
Wear Pads Worn heavy
Boom Length 80' Extended boom length; 33' Jib retracted
Boom Angle Indicator
Limited Function Check The main crane components functioned when checked without a load.
(41)


Specialty
Description Rating Details  
Jib 33' Long; Swing Away (side mounted)
Main Load Block None supplied
Overhaul Ball Swiveler Ball
Counterweights (1) Counterweight
(6)
 

Oil Sample Analysis
  Engine Transmission Hydraulic
date of analysis Dec 18, 2012 Dec 18, 2012 Dec 18, 2012
Silicon 1 PPM 6 PPM 7 PPM
Lead 0 PPM 16 PPM 2 PPM
Tin 0 PPM 1 PPM 2 PPM
Copper 2 PPM 158 PPM 45 PPM
Aluminum 3 PPM 3 PPM 4 PPM
Silver 0 PPM 0 PPM 0 PPM
Nickel 0 PPM 1.6 PPM 0.9 PPM
Chromium 0.6 PPM 0.8 PPM 1.2 PPM
Iron 8 PPM 29 PPM 10 PPM
Glycol NEG N/A N/A
Water NEG NEG NEG
Fuel <5% N/A N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.