Home Page / 2005 Tower Light SuperLight VT1 Light Tower
 
Sold on
1/29/14
Winning Bid
€1,700
# of Bids
9
SOLD!
ITEM DETAILS
Meter Broken
9 kVA, 5 Lamps, Kubota D1105 Engine, Electric Mast Winch, Pintle Ring, Power Receptacles

Inspected by IronPlanet.

Your purchase is protected by our Ironclad Assurance.

IronPlanet Inspection Report



Please Note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark (on or near data plate) Yes
  
CE Certificate Available Yes
Paint Recently painted
  
Sheet Metal (Fiberglass) Condition Minor dents
 (5)


Control Station Ground
Description Rating Details  
Hour Meter Hour meter missing - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
  
Gauges Operational
  
Function Controls Loose; Worn
  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Warning Lights Operational
Limited Function Check The main components operated except as noted.
 (6)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Control Label None found
  
Blow by @ idle (subjective observation) No noticeable vapor or pressure
  
Starter Operational
  
Fuel System Operational
  
Exhaust System Loose; Weld repair; Leaks at connections
  
Radiator Fan guard missing
  
Oil Leaks Dripping Leak: Side of engine.
  
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check (Engine) The engine started and ran.
 (15)


Chassis
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Axle Condition
  
Tire Condition Minor cuts and gouges
  
Wheel Condition Rusty
  
Wheel Studs
  
Power Receptacle Functional Yes
  
Frame Rails/ Main Beams Condition
  
Landing Gear / Tongue Jack Weld repair
  
Outrigger Condition Weld repairs
  
 (23)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator Manufacturer: Linz electric; 9 KVA rating; Functionally checked to power lights
  
Light Tower Mast
  
 (9)
 

Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data