ITEM DETAILS
Mileage
20,956 Hours
VIN
625 kVA, 500 kW, 480 Volts 3 Phase, Volvo TAD-1631GE Engine, Fuel Tank, Container Enclosure, T/A, Air Brakes, 10.00-20 Tires SERIAL # 2160035894WA523942-0300

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Condition Click here to open photos and videos of this item.  
Sheet Metal Condition Click here to open photos and videos of this item.  
Steps and Grab Handles Click here to open photos and videos of this item.  
(12)


Control Station
Description Rating Details  
Oil Pressure 42 PSI Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 20,956 Hours Click here to open photos and videos of this item.  
Hour Meter 20,956 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational. Click here to open photos and videos of this item.  
(8)


Engine
Description Rating Details  
Emission Certification Label US EPA certification label Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Oil Leaks Side of engine Click here to open photos and videos of this item.  
Fuel Leaks None seen
Cooling System Leaks None seen
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) The engine started and ran. Click here to open photos and videos of this item.  
(12)


Electrical
The generator was not load checked during the inspection. IronPlanet does not guarantee the generators ability to run at its full rated kW output.
Description Rating Details  
Generator Make and Model Marathon; 572RSL4027 generator; Serial#: WA-523942-0300 Click here to open photos and videos of this item.  
Disconnect Switch Functional Click here to open photos and videos of this item.  
Cables and Connections Click here to open photos and videos of this item.  
Emergency Shut Off Switch Operational Click here to open photos and videos of this item.  
Limited Function Check The generator was not checked for electrical output.
(9)


Trailer Chassis
Description Rating Details  
Trailer Brakes Air Click here to open photos and videos of this item.  
Limited Function Check - Brakes The brakes were not operationally checked.
Tire Condition Click here to open photos and videos of this item.  
Wheel Condition
Axle Condition Click here to open photos and videos of this item.  
Springs/Hangers Condition Click here to open photos and videos of this item.  
Tongue/ Hitch Condition Click here to open photos and videos of this item.  
Marker Lights Functional Not operationally checked
Brake Lights Functional Not operationally checked Click here to open photos and videos of this item.  
License Plate Light Functional Not operationally checked Click here to open photos and videos of this item.  
Frame Rails/ Main Beams Condition Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Deck/ Floor Condition Click here to open photos and videos of this item.  
(19)
 

Oil Sample Analysis
  engine
date of analysis Sep 20, 2016
Lead 0 PPM
Chromium 0 PPM
Copper 0 PPM
Silver 2.14 PPM
Nickel 0 PPM
Tin 3.73 PPM
Aluminum 1.61 PPM
Silicon 12.76 PPM
Iron 5.73 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Related Equipment (Both Live and Sold)
220 kVA, 220/480 Volts 3 Phase, John Deere ...
220 kVA, 220/480 Volts 3 Phase, John Deere Diesel Engine, Bottom Mounted Fuel Tank, Insulated Enclosure, T/A, Pintle Ring, Surge Brakes, ST235/80R16 Tires, The engine could not be stared. The main components could not be operationally checked. There is a ...
400 kVA, 240/480 Volts 3 Phase, 110V Receptacles, ...
400 kVA, 240/480 Volts 3 Phase, 110V Receptacles, 230V Receptacles, Volvo TAD1241GE Engine, Bottom Mounted Fuel Tank, Insulated Enclosure, Tri/A, Pintle Ring, Electric Brakes, LT235/85R16 Tires. The engine could not be started. The generator has been removed and is missing. ...
220 kVA, 240/480 Volts 3 Phase, Volvo TAD741GE ...
220 kVA, 240/480 Volts 3 Phase, Volvo TAD741GE Engine, Bottom Mounted Fuel Tank, T/A, Pintle Ring, Surge Brakes, LT235/85R16 Tires. Engine started but shut down, the seller states it possibly has a blown head gasket. The fuel caps are missing. ...
144 kVA, 115 kW, 277/480 Volts 3 Phase, ...
144 kVA, 115 kW, 277/480 Volts 3 Phase, Electrical Switch Gear, John Deere 6068HF Engine, Fuel Tank, Insulated Enclosure, T/A, Gooseneck, ST235/80R16 Tires. The engine started and ran. The generator was not checked for electrical output. The main components appear ...