Home Page / 2004 Princeton E2-3RX Piggyback Forklift
 
Previous Next
Sold on
12/2/16
Winning Bid
US $7,000
# of Bids
83
SOLD!
ITEM DETAILS
1,442 Hours
5,000 lbs. Max. Weight Capacity, 2 Stage Mast, 118” Max Lift Height, 99” Lowered Mast Height, 48” Forks, Side Shift, Volkswagon 1.9L Engine, Diesel, Open Operator Station

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
(11)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Inoperable
Seat Belts Operational
Current Safety Manual No
Current Operator/Maintenance Manual No


Control Station
Description Rating Details  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Warning Lights Operational; Voltage light stays on Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 1,441 Hours; Difficult to see Click here to open photos and videos of this item.  
Hour Meter 1,442 Hours; Operational hour meter; Difficult to see - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components operated except as noted. Click here to open photos and videos of this item.  
(11)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Certification Label US EPA certification label Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) Recirculating system
Starter Intermittent
Fuel System Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting. Engine only runs with jump box connected. Click here to open photos and videos of this item.  
(10)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(5)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Steering Cylinders Click here to open photos and videos of this item.  
Mast Lift Cylinders Dripping leak on the left cylinder; Dripping leak on the right cylinder Click here to open photos and videos of this item.  
Mast Tilt Cylinders Click here to open photos and videos of this item.  
Side Shift Cylinder Click here to open photos and videos of this item.  
Fork Positioning Cylinder (on fork carriage) Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(12)


Chassis Lift
A propane fuel tank will not be included with this unit at the time of sale. IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Mast/Boom Condition Click here to open photos and videos of this item.  
Chain / Tensioners Click here to open photos and videos of this item.  
Carriage Rollers and Guides Click here to open photos and videos of this item.  
Load Back Rest Click here to open photos and videos of this item.  
Side Shift Yes Click here to open photos and videos of this item.  
Forks Click here to open photos and videos of this item.  
Steering Linkage Heavy Movement Click here to open photos and videos of this item.  
Frame Condition Weld repairs/ plated Click here to open photos and videos of this item.  
Park Brake Click here to open photos and videos of this item.  
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Left Front Tire Click here to open photos and videos of this item.  
Left Rear Tire Click here to open photos and videos of this item.  
Right Front Tire Click here to open photos and videos of this item.  
Wheel Condition Metal erosion
Wheel Studs Missing 1 nut
(26)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Nov 16, 2016 Nov 16, 2016
Lead 2.26 PPM 0 PPM
Chromium 0 PPM 0 PPM
Copper 0 PPM 0 PPM
Silver 2.5 PPM 0.57 PPM
Nickel 0 PPM 0 PPM
Tin 4.21 PPM 1.91 PPM
Aluminum 4.15 PPM 1.92 PPM
Silicon 9.34 PPM 22.6 PPM
Iron 19.35 PPM 15.12 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.