Home Page / Forklifts / 2009 Hyster H70FT Pneumatic Tire Forklift
 

2009 Hyster H70FT Pneumatic Tire Forklift (#403863)

Search for other Forklifts - Pneumatic Tire items

Winning Bid: US $9,000  
# of Bids: 6   View Bid History
Sold on: : 8/16/12
Auction Type: Featured Auction
SOLD!
Features: 4,400 lb. Max Weight Capacity, 3 Stage Mast, 229" Max Lift Height, 104" Lowered Height, 48" Forks, Auxiliary Hydraulic Plumbing, GM Engine, LP, Open Operator Station.
Meter Reading: 4,970 Hours
Serial Number:
Location: North Carolina, United States
Zip/Postal Code:28106
(Charlotte-Gastonia-Rock Hill, NC-SC area)
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Recently painted; See photos for condition
Sheet Metal (fiberglass) Condition No visible damage; Minor dents; Scrapes; See photos for condition
General Appearance #1
 
Control Station
Seats/Armrests Inoperable slide or adjustment
Seat Belts Operational
Horn Operational
Hydraulic Controls
Steering Control
Drivetrain Controls
Oil Pressure Digital
Warning Lights Operational
Travel Alarm Inoperable
Gauges Operational
Hour Meter 4,970 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Limited Function Check (cs) The main components operated except as noted.
Hour Meter
 
Engine
Fuel Type LPG
Emission Control Label None found
Blow by @ idle (subjective observation) Minor
Starter Operational
Fuel System Operational
Exhaust System No visible damage
Radiator
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check (Engine) The engine started and ran.
Engine #1
 
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Transmission Operational
Front Drive Axle
Limited Function Check The drivetrain was operational.
Drivetrain #1
 
Hydraulics
Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses (Hydraulics)
Steering Cylinders Minor to moderate pin and bushing movement
Mast Lift Cylinders Minor to moderate pin and bushing movement
Fork Tilt Cylinders Fluid accumulation on the left cylinder; Minor to moderate pin and bushing movement
Limited Function Check The hydraulic system was operational except as noted.
Hydraulics #1
 
Chassis Lift
A propane fuel tank will not be included with this unit at the time of sale. IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Mast/Boom Condition Moderate wear
Chain / Tensioners Moderate wear
Carriage Rollers and Guides Moderate wear
Load Back Rest Missing
Forks
Steering Linkage Minor to moderate movement
Frame Condition
Master Cylinder/Brake Control
Park Brake Inoperable
Limited Function Check The service brakes performed. The park brake would not hold the machine.
Tire Condition See photos
Wheel Condition
Wheel Studs
Chassis Lift #1

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2013 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet℠, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.