Home Page / 2013 Gallmac TG10 Wheel Excavator
 
Previous Next
Auction Closed on
10/20/16
Opened At
US $140,000
NOT SOLD
ITEM DETAILS
64 Hours
Enclosed Cab, Air Conditioner, Heater, 16" Bucket, Auxiliary Hydraulic Plumbing, 2-Piece Boom, 6' 8" Stick, 7' 6" Blade, Rear Stabilizers, 16/70-20 Tires.

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark (on or near data plate) No
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
(9)


Safety
Description Rating Details  
Travel Alarm Operational
Horn Operational
Seat Belts Operational
Safety Lock Out/Stop Click here to open photos and videos of this item.  
Swing Brake
Current Safety Manual No
Current Operator/Maintenance Manual No
(2)


Control Station
Description Rating Details  
Steering Control Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter/Odometer (Start) 63.6 Hours Click here to open photos and videos of this item.  
Hour Meter/Odometer 64.6 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner Operational
Heater Not operationally checked Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational. Click here to open photos and videos of this item.  
(18)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Certification Label US EPA certification label Click here to open photos and videos of this item.  
A/C Compressor Operational
Blow by @ idle (subjective observation) Minor Click here to open photos and videos of this item.  
Starter Operational
Fuel System Operational Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks None seen
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) The engine started and ran.
(8)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors
Front Drive Axle Click here to open photos and videos of this item.  
Rear Drive Axle Click here to open photos and videos of this item.  
Rear Axle Oscillating Pin Click here to open photos and videos of this item.  
Drive Line Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(8)


Hydraulics
Description Rating Details  
Pumps (Hydraulics)
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Not operationally checked Click here to open photos and videos of this item.  
Swing Motor Click here to open photos and videos of this item.  
Hydraulic Center Swivel
Boom Lift Cylinder(s) Click here to open photos and videos of this item.  
Stick Cylinder Click here to open photos and videos of this item.  
Bucket Cylinder Click here to open photos and videos of this item.  
Blade Lift Cylinder Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(19)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Boom Condition Click here to open photos and videos of this item.  
Stick Condition Click here to open photos and videos of this item.  
Boom Base Pin and Bushings Click here to open photos and videos of this item.  
Pin and Bushings Boom to Stick Click here to open photos and videos of this item.  
Pins and Bushings Stick to Coupler Click here to open photos and videos of this item.  
Turntable Bearing Click here to open photos and videos of this item.  
Limited Function Check The main components were operational in a limited check.
Stabilizers Operational
Steering Linkage Click here to open photos and videos of this item.  
Frame Condition Click here to open photos and videos of this item.  
Limited Function Check The main chassis components functioned during a limited check.
Brake Control Click here to open photos and videos of this item.  
Park Brake
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Wheel Condition
Wheel Studs, Nuts, Lugs
(17)


Specialty
Description Rating Details  
Excavator Bucket Condition Click here to open photos and videos of this item.  
Teeth / Adapters Click here to open photos and videos of this item.  
Blade Condition Click here to open photos and videos of this item.  
Blade Cutting Edge Condition Click here to open photos and videos of this item.  
(6)
 

Oil Sample Analysis
  engine
date of analysis Sep 15, 2016
Lead 1.46 PPM
Chromium 0 PPM
Copper 0 PPM
Silver 2.69 PPM
Nickel 0.08 PPM
Tin 0 PPM
Aluminum 3.97 PPM
Silicon 31.44 PPM
Iron 21.77 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.