Previous Next
Sold on
4/13/12
Winning Bid
US $31,000
Won using Buy Now Price
# of Bids
2
SOLD!
ITEM DETAILS
Meter Reading
3,287 Hours
Serial #
Enclosed Cab, A/C, Heater, 9' 10" Stick, 32" Track Shoes, 48" Bucket, Manual Thumb

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
CE Mark No
Paint See photos for condition; Scratches; Chips
Sheet Metal (fiberglass) Condition Dents; Scrapes; Surface rust in areas; Bent panels; Left rear side panel bent; Left cab post bent at lower front glass area; See photos for condition
Steps/Ladders No visible damage; See photos for condition
Hand Rails No visible damage; See photos for condition
(5)


Control Station
Description Rating Details  
Mirrors Missing; Damaged mounting bracket
Glass See photos for condition; Front lower and top: Cracked; Front: Plexiglass; Lower plexiglass; Weather stripping missing or damaged
Seats/Armrests See photos for condition
Seat Belts Inoperable latch; Missing latch
Horn Inoperable
Safety Lock Out/Stop
Hydraulic Controls
Steering Control
Drivetrain Controls
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Exterior Lights Boom light broken; Top right inoperable
Warning Lights Operational; Alternator charge warning light on monitor panel on
Travel Alarm Inoperable
Gauges Operational
Hour Meter/Odometer (Start) 3286 Hours
Hour Meter/Odometer 3,287 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner Inoperable; When A/C and blower fan turned on, the engine cuts off Click here to open photos and videos of this item.  
Heater Inoperable
Limited Function Check The main components operated except as noted.
(16)


Engine
Description Rating Details  
Make and Model Cummins 5.9L engine; Serial #: 21471427
Fuel Type Diesel
Emission Certification Label US EPA certification label Click here to open photos and videos of this item.  
A/C Compressor Compressor will not engage
Blow by @ idle (subjective visual observation) Minimal Click here to open photos and videos of this item.  
Starter Operational
Turbo or Blower Operational
Fuel System Operational
Exhaust System See photos for condition; Muffler exhaust outlet is rusted out; Exhaust pipe rusted out; Muffler is cracked
Radiator Minor plugging of fins
Oil Leaks See photos; Fluid Accumulation: Valve cover; Fluid Accumulation: Side of engine; Fluid Accumulation: Front of engine; Fluid Accumulation: Oil Pan; Fluid Accumulation: Rear of engine
Fuel Leaks None seen; See photos
Cooling System Leaks None seen; See photos
Limited Function Check (Engine) The engine started and ran. See oil report.
(10)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors
Final Drives
Limited Function Check The drivetrain functioned without a load.
(2)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses (Hydraulics) Retaining bracket on bucket cylinder tube broken
Swing Motor
Boom Lift Cylinder(s) Dripping leak on the left cylinder; Dripping leak on the right cylinder; Rust pitting in the chrome on the left cylinder; Rust pitting in the chrome on the right cylinder; Minor to moderate pin and bushing movement
Stick Cylinder Fluid accumulation; Appears to have internal seepage; Minor to moderate pin and bushing movement
Bucket Cylinder Minor to moderate pin and bushing movement
Limited Function Check The hydraulic system was operational without a load. See oil report.
(12)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Boom Condition
Stick Condition Rusted on sides at weld on plates
Boom Base Pin and Bushings Minor to moderate movement
Pin and Bushings Boom to Stick Minor to moderate movement
Pin and Bushings Stick to Bucket Minor to moderate movement
Stick Length 9' 10'' Stick Length
Turntable Bearing Minor to moderate movement
Bottom Covers Oily
Roller Frames
Limited Function Check The main components were operational with movement as indicated.
(13)


Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Overall width (outside to outside of shoes) 11' 2'' Overall width for transport
Track Tensioners See photos for condition
Shoe Width 32" track shoes
Grouser Height Left Side: 24 mm; Right Side: 24 mm
Track links See photos for condition
Pins and Bushings Turned? No
Pins and bushings See photos for condition
Carrier Rollers See photos for condition
Track Rollers See photos for condition
Idlers See photos for condition
Sprockets See photos for condition


Rubber Track Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
(14)


Specialty
Description Rating Details  
Excavator Bucket Condition 48'' bucket
Backhoe / Excavator Bucket Shanks and Teeth
Thumb Manual thumb
(7)
 

Oil Sample Analysis
  Engine Hydraulic
date of analysis Dec 05, 2011 Dec 05, 2011
Silicon 15 PPM 6 PPM
Lead 6 PPM 0 PPM
Tin 2 PPM 1 PPM
Copper 5 PPM 4 PPM
Aluminum 19 PPM 2 PPM
Silver 0.1 PPM 0.1 PPM
Nickel 1.3 PPM 0 PPM
Chromium 6.9 PPM 0.2 PPM
Iron 96 PPM 6 PPM
Glycol NEG N/A
Water NEG NEG
Fuel <5% N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.