ITEM DETAILS
Meter Reading
225 Hours
Serial #
Cummings Engine, 20" x 17' Conveyor, 12" Track Shoes Contact Majida(925-394-7920) Or Make an Offer below. Veuillez contacter Majida sur le (925-394-7920) ou mettez votre offre.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Motor Vehicle Safety Standards Label No; No plate found
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
(19)


Safety
Description Rating Details  
Travel Alarm Operational
Safety Lock Out/Stop Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Some not operational Click here to open photos and videos of this item.  
Hour Meter/Odometer (Start) 225.6 Hours Click here to open photos and videos of this item.  
Hour Meter/Odometer 225.6 Hours - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational as noted.
(8)


Engine
Description Rating Details  
Emission Certification Label None found Click here to open photos and videos of this item.  
Blow by @ idle (subjective visual observation) Minor
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen Click here to open photos and videos of this item.  
Fuel Leaks None seen Click here to open photos and videos of this item.  
Cooling System Leaks None seen Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) The engine started and ran.
(12)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Click here to open photos and videos of this item.  
Final Drives Click here to open photos and videos of this item.  
Drive Line Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(10)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Dripping underneath the tank Click here to open photos and videos of this item.  
Hoses Click here to open photos and videos of this item.  
Cylinder(s) Click here to open photos and videos of this item.  
Cylinder Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(18)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Condition Click here to open photos and videos of this item.  
Leg Condition Click here to open photos and videos of this item.  
Leg Slide Wear Plates Click here to open photos and videos of this item.  
Conveyor Belt Condition Click here to open photos and videos of this item.  
Conveyor Dimensions Length 17'; Belt width 20" Click here to open photos and videos of this item.  
Trimmer Click here to open photos and videos of this item.  
Limited Function Check The main chassis components functioned when checked without a load.
Brake Type Hydrostatic
Park Brake
(12)


Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Overall width (outside to outside of shoes) 7' 6" Overall width
Track Tensioners Operational
Shoe Width 12" track shoes Click here to open photos and videos of this item.  
Grouser Height Left Side: 15mm; Right Side: 15mm Click here to open photos and videos of this item.  
Track links Click here to open photos and videos of this item.  
Pins and Bushings Turned? No Click here to open photos and videos of this item.  
Pins and bushings Click here to open photos and videos of this item.  
Carrier Rollers Click here to open photos and videos of this item.  
Track Rollers Click here to open photos and videos of this item.  
Idlers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
(19)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Apr 17, 2018 Apr 17, 2018
Lead 8.19 PPM 9.64 PPM
Chromium 3.01 PPM 0.05 PPM
Copper 10.79 PPM 9.92 PPM
Silver 0 PPM 0 PPM
Nickel 1.24 PPM 1.21 PPM
Tin 0 PPM 0 PPM
Aluminum 0 PPM 0 PPM
Silicon 0.17 PPM 0 PPM
Iron 22.79 PPM 0 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.