Meter Reading
3,190 Hours
Serial #

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.
Summary Protected by IronClad Assurance Protected by IronClad Assurance®
This machine appears to be in good overall condition. The engine and hydraulics seem to be in good working condition. The sheet metal and paint are fair.


General Appearance
Description Rating Details  
sheet metal (fiberglass) condition Dents and scrapes throughout. There is surface rust in areas where the paint is missing. Click here to open photos and videos of this item.  
paint Faded, chipped and scratched Click here to open photos and videos of this item.  
(2)


Operator Station
Description Rating Details  
steps/ladders
hand rails Click here to open photos and videos of this item.  
glass
seats/armrests Click here to open photos and videos of this item.  
seat belts INOPERABLE - The locking mechanism is missing.
warning lights/alarms
safety alarms INOPERABLE
oil pressure The warning light went out when the engine was started.
hour meter operational Yes
horn
hydraulic controls
steering controls Click here to open photos and videos of this item.  
powertrain controls Click here to open photos and videos of this item.  
limited function check The components that were checked performed properly with wear and damage as noted above.
(4)


Engine
Description Rating Details  
hour meter 3190 hours
make & model Deutz F3L 1011 F Click here to open photos and videos of this item.  
serial # 00300739
emission control label None Seen
fuel type Diesel
starter
battery
exhaust system Click here to open photos and videos of this item.  
cylinder head gasket
oil dipstick tube & bonnet
blowby (checked at idle) Minor
valve cover gasket
oil pan & gasket
injector pump
fuel line & injector leaks None Seen
limited function check The engine started easily and ran well with minor smoke that cleared up. There is a slight oil seepage at the front cover.
(2)


Powertrain
Description Rating Details  
transmission type Hydrostatic
limited function check The powertrain responded well with no unusual noises.


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
articulating-center pins No noticeable play Click here to open photos and videos of this item.  
belly pans
steering linkage Minor wear
steering wheel play Minor play
limited function check The main components functioned properly with minor wear at the pivot points.
brake type Hydrostatic dynamic
brake lines/ hoses
park brake
limited function check The brakes performed well, stopping and holding the machine.
drum type Smooth Click here to open photos and videos of this item.  
drum width 47" Click here to open photos and videos of this item.  
drum condition
drum surface scraper or cleaner Moderate wear Click here to open photos and videos of this item.  
water system Undetermined - Ambient temperature too cold to operate. Click here to open photos and videos of this item.  
limited function check The components that could be checked performed properly with wear as noted.
(5)


Hydraulics
Description Rating Details  
pumps Click here to open photos and videos of this item.  
valves
hoses Weather checking and chafing. Click here to open photos and videos of this item.  
cylinders
cylinder pins and bushings Minor wear
drive motors Click here to open photos and videos of this item.  
vibrator motors The vibrator works at all speeds. Click here to open photos and videos of this item.  
limited function check The system functioned well with no unusual noises or visible leaks. See the oil sample analysis for the hydraulic system.
(4)


Additional Photos
(4)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Feb 04, 2003 Feb 04, 2003
analysis by Spectro Spectro
Tin 0 PPM 2 PPM
Chromium 0.1 PPM 0.2 PPM
Copper 0 PPM 424 PPM
Nickel 0.4 PPM 0.1 PPM
Lead 0 PPM 11 PPM
Magnesium 60 PPM 61 PPM
Water 0 % 0 %
Silver 0 PPM 0.1 PPM
Iron 10 PPM 20 PPM
Silicon 5 PPM 2 PPM
Sodium 3 PPM 6 PPM
Aluminum 3 PPM 2 PPM
Glycol N N
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.