Back to Search Results / 2009 Caterpillar 257B2 Compact Track Loader
 

2009 Caterpillar 257B2 Compact Track Loader (#382932)

Search for other Compact Track Loaders items

Winning Bid: US $30,000
Won using: Win It Now
 
# of Bids: 1   View Bid History
Sold on: : 6/26/12
Auction Type: Daily Marketplace
SOLD!
Features: Enclosed Cab, A/C, Heater, Auxiliary Hydraulic Plumbing, 15" Track Belts, Manual Coupler, GP Bucket
Meter Reading: 268 Hours
Serial Number:
Location: Quebec, Canada
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Touch up paint; Scratches
Sheet Metal (fiberglass) Condition Scrapes; Surface rust in areas
Steps/Ladders No visible damage
Hand Rails No visible damage
General Appearance #1
 
Control Station
Mirrors
Glass
Seats/Armrests
Seat Belts Operational
Horn Operational
Control Lock Lever
Hydraulic Controls
Drivetrain Controls Controls stick
Engine Controls
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Exterior Lights Operational Yes
Engine Warning Lights Operational
Travel Alarm Operational
Gauges Operational
Hour Meter 268.2 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Air Conditioner Operational
Heater Operational
Limited Function Check The main components are in place and operational.
Hour Meter
 
Engine
Make and Model Caterpillar C2.2 engine; Serial #: CYS07579
Fuel Type Diesel
Emission Control Label US EPA certification label
Blow by @ idle (subjective observation) Minimal
Starter Operational
Turbo or Blower Operational
Fuel System Operational
Exhaust System Leaks at connections
Radiator
Oil Leaks Fluid Accumulation: Valve cover
Fuel Leaks None seen
Cooling System Leaks Fluid Accumulation: Radiator hose
Limited Function Check After jump starting the engine ran. See oil report.
Emission Control Label
 
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Drive Motors Only one speed working
Limited Function Check The drivetrain functioned without a load with only one speed working.
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Frame Condition
Belly pans
Roller Frames
Lift Arm Condition
Chassis to Arm Pins Minor to moderate movement
Quick Coupler to Arms Pins Minor to moderate movement; One pin not locking
Limited Function Check The main components were operational with movement as indicated.
Chassis #1
 
Hydraulics
Pumps (Hydraulics)
Valves
Hydraulic Tank
Hoses (Hydraulics)
Auxiliary Hydraulic Plumbing Wet with residue; Not operationally checked.
Loader Lift Cylinders Minor to moderate pin and bushing movement
Bucket Tilt Cylinders Minor to moderate pin and bushing movement
Limited Function Check The hydraulic system was operational without a load. See oil report.
Hydraulics #1
 
Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Overall Machine Width (Outsides of tracks.) 5' 6 1/2" Overall width
Grouser Height Measurement Left side: 19 mm; Right side: 19 mm
Track Belt Width 15" track belts
Track Belt Condition See photos for condition; Cuts; Chunks out of covering; Damaged drive lugs; Edges torn; Damage to the inside of the track belts
Rubber Belt Drive Lugs See photos for condition; Torn/damaged lugs
Track Tensioners See photos for condition
Carrier Rollers See photos for condition; Worn with cuts and chunking
Front Idler Wear See photos for condition
Rear idler wear See photos for condition
Track Rollers See photos for condition; Worn with cuts and chunking
Sprockets See photos for condition; Minor wear
Undercarriage #1
 
Specialty
Quick Coupler Manual coupler functional; One pin not locking
Loader Bucket Condition 6' 2 1/4" General purpose loader bucket; Holes; Dented
Loader Bucket Cutting Edge Reversible-not turned
Specialty #1
Oil Sample Analysis Engine Hydraulic
date of analysis Apr 18, 2012 Apr 18, 2012
Silicon 8 PPM 3 PPM
Lead 4 PPM 3 PPM
Tin 1 PPM 0 PPM
Copper 44 PPM 2 PPM
Aluminum 8 PPM 1 PPM
Silver 0.1 PPM 0.2 PPM
Nickel 1.6 PPM 0.8 PPM
Chromium 1.3 PPM 0 PPM
Iron 42 PPM 6 PPM
Glycol NEG N/A
Water NEG NEG
Fuel <5% N/A

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2013 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet℠, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.