ITEM DETAILS
1,094 Hours
Open Operator Station, Auxiliary Hydraulic Plumbing, 11" Track Belts, Manual Coupler, 48" General Purpose Smooth Edge Bucket

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
Exterior Lights Operational; Some not operational Click here to open photos and videos of this item.  
(7)


Safety
Description Rating Details  
Travel Alarm Inoperable
Horn Inoperable
Seat Belts Operational
Safety Lock Out/Stop Click here to open photos and videos of this item.  
Current Safety Manual No
Current Operator/Maintenance Manual No
(2)


Control Station
Description Rating Details  
Seats/Armrests Inoperable slide or adjustment; Seat not properly bolted to cab Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Drivetrain Controls Pulled unevenly Click here to open photos and videos of this item.  
Engine Controls Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. Click here to open photos and videos of this item.  
Warning Lights Some inoperable Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 1,093 Hours Click here to open photos and videos of this item.  
Hour Meter 1,094 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components operated except as noted. Click here to open photos and videos of this item.  
(12)


Engine
Description Rating Details  
Emission Certification Label None found Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) No noticeable vapor or pressure; Recirculating system Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Broken exhaust pipe Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks Dripping leak under center of machine from unknown source.
Fuel Leaks None seen
Cooling System Leaks None seen
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) The engine started and ran.
(6)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Drive Motors Pulled unevenly Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational as noted.
(2)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses (Hydraulics) Click here to open photos and videos of this item.  
Auxiliary Hydraulic Plumbing Not operationally checked Click here to open photos and videos of this item.  
Loader Lift Cylinders Dripping leak on the left cylinder Click here to open photos and videos of this item.  
Bucket Tilt Cylinders Dripping leak on the left cylinder; Dripping leak on the right cylinder Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational; Dripping leak under center of machine from unknown source.
(8)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Frame Condition Weld repairs Click here to open photos and videos of this item.  
Belly pans Missing Click here to open photos and videos of this item.  
Lift Arm Condition Click here to open photos and videos of this item.  
Chassis to Arm Pins Click here to open photos and videos of this item.  
Quick Coupler to Arms Pins Click here to open photos and videos of this item.  
Limited Function Check The main chassis components were operational in a limited check.
(6)


Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Description Rating Details  
Overall Machine Width (Outsides of tracks.) 46 1/2" Overall width
Roller Frames Click here to open photos and videos of this item.  
Grouser Height Measurement 25 mm
Track Belt Condition Click here to open photos and videos of this item.  
Rubber Belt Drive Lugs Click here to open photos and videos of this item.  
Track Tensioners Operational
Front Idler Wear Click here to open photos and videos of this item.  
Rear idler wear Click here to open photos and videos of this item.  
Track Rollers Click here to open photos and videos of this item.  
Sprockets Click here to open photos and videos of this item.  
(13)


Specialty
Description Rating Details  
Quick Coupler Operational Click here to open photos and videos of this item.  
Loader Bucket Condition Click here to open photos and videos of this item.  
(4)
 
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.