Home Page / Gyro-Trac GT-25 Mulcher
 
Previous Next
Sold on
9/30/16
Winning Bid
US $41,000
# of Bids
4
SOLD!
ITEM DETAILS
3,008 Hours
Enclosed Cab, Air Conditioner, Heater, Cummins Engine, 84" Feed Opening

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Scratches and chips Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Some bolts missing Click here to open photos and videos of this item.  
Glass Scratched plexiglass Click here to open photos and videos of this item.  
Exterior Lights Operational Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
(10)


Control Station
Description Rating Details  
Chipper Drive Controls Click here to open photos and videos of this item.  
Safety Lock Out/Stop Operational Click here to open photos and videos of this item.  
Warning Lights Operational; Hydraulic pressure light flashes intermittently Click here to open photos and videos of this item.  
Oil Pressure The fault indicator shuts off after the engine oil pressure rises. The gauge registers in the operating range. 34 PSI Click here to open photos and videos of this item.  
Gauges Operational; Fuel gauge inoperable Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 3,008 Hours Click here to open photos and videos of this item.  
Hour Meter 3,008.5 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components operated except as noted. Click here to open photos and videos of this item.  
(13)


Engine
Description Rating Details  
Emission Certification Label US EPA certification label Click here to open photos and videos of this item.  
A/C Compressor Operational; Red Dot unit Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) Visible Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Minor plugging of fins Click here to open photos and videos of this item.  
Oil Leaks No dripping leaks Click here to open photos and videos of this item.  
Fuel Leaks Fuel line; Fuel tank Click here to open photos and videos of this item.  
Cooling System Leaks None seen Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) The engine started and ran. Click here to open photos and videos of this item.  
(14)


Drive System
Description Rating Details  
Engine mounts Click here to open photos and videos of this item.  
Chipping wheel Click here to open photos and videos of this item.  
Chipping blades Some uneven wear Click here to open photos and videos of this item.  
Limited Function Check - Chassis The main components were operational when checked without a load.
(14)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Hydraulic Motors Covered Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Braid exposure Click here to open photos and videos of this item.  
Cylinder(s) Click here to open photos and videos of this item.  
Cylinder Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational.
(10)
 

Oil Sample Analysis
  engine
date of analysis Sep 22, 2016
Lead 0 PPM
Chromium 0 PPM
Copper 0 PPM
Silver 3.2 PPM
Nickel 0 PPM
Tin 0.09 PPM
Aluminum 8.86 PPM
Silicon 17.28 PPM
Iron 73.39 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.