ITEM DETAILS
Meter Reading
1,656 Hours
Serial #
Enclosed Cab, A/C, Heater, 8' Broom, Water System, John Deere 4039DF001 Engine

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Paint Click here to open photos and videos of this item.  
Sheet Metal (Fiberglass) Condition Click here to open photos and videos of this item.  
Glass Cracked side glass Click here to open photos and videos of this item.  
Exterior Lights Some not operational Click here to open photos and videos of this item.  
Steps/Ladders Click here to open photos and videos of this item.  
Hand Rails Click here to open photos and videos of this item.  
(12)


Safety
Description Rating Details  
Travel Alarm Inoperable
Seat Belts Operational
Current Safety Manual No
Current Operator/Maintenance Manual No
(1)


Control Station
Description Rating Details  
Mirrors Click here to open photos and videos of this item.  
Seats/Armrests Click here to open photos and videos of this item.  
Hydraulic Controls Click here to open photos and videos of this item.  
Steering Control Click here to open photos and videos of this item.  
Drivetrain Controls Click here to open photos and videos of this item.  
Oil Pressure 45 PSI Click here to open photos and videos of this item.  
Warning Lights Operational Click here to open photos and videos of this item.  
Gauges Operational Click here to open photos and videos of this item.  
Hour Meter/Odometer (Start) 1,656 Hours Click here to open photos and videos of this item.  
Hour Meter/Odometer 1,656 Hours - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Air Conditioner The ambient temperature is too cold to check.
Heater Operational Click here to open photos and videos of this item.  
Limited Function Check The main components operated except as noted. Click here to open photos and videos of this item.  
(18)


Engine
Description Rating Details  
Emission Certification Label None found
A/C Compressor In place; Ambient temperature too cold to check operation. Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen
Fuel Leaks None seen
Cooling System Leaks Water pump Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) The engine started and ran. Click here to open photos and videos of this item.  
(12)


Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Description Rating Details  
Transmission Operational Click here to open photos and videos of this item.  
Drive/Propel Motors Click here to open photos and videos of this item.  
Rear Drive Axle Click here to open photos and videos of this item.  
Limited Function Check The drivetrain was operational.
(6)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Broom Mount Frame Click here to open photos and videos of this item.  
Broom Condition Click here to open photos and videos of this item.  
Water System Unable to test Click here to open photos and videos of this item.  
Steering Linkage Click here to open photos and videos of this item.  
Steering Wheel Play
Limited Function Check - Chassis The components that were checked were operational except as noted.
Master Cylinder/Brake Control Click here to open photos and videos of this item.  
Brake Lines/Hoses
Park Brake Click here to open photos and videos of this item.  
Limited Function Check - Brakes The brake system functioned, stopping and holding the machine.
Tire Size P225/75R15 Front tires; P265/75R15 Rear tires; LF Goodyear; LR Dunlop; RR Uniroyal; RF Goodyear Click here to open photos and videos of this item.  
Tire Condition Front tires are foam filled and in poor condition. Click here to open photos and videos of this item.  
Wheel Condition
(19)


Hydraulics
See photos for condition
Description Rating Details  
Pumps (Hydraulics) Click here to open photos and videos of this item.  
Hydraulic Motors Click here to open photos and videos of this item.  
Valves Click here to open photos and videos of this item.  
Hydraulic Tank Click here to open photos and videos of this item.  
Hoses Damaged Click here to open photos and videos of this item.  
Cylinder(s) Click here to open photos and videos of this item.  
Cylinder Pins and Bushings Click here to open photos and videos of this item.  
Limited Function Check The hydraulic system was operational. Click here to open photos and videos of this item.  
(12)
 

Oil Sample Analysis
  engine hydraulic
date of analysis Jan 19, 2017 Jan 19, 2017
Lead 0 PPM 0.23 PPM
Chromium 0 PPM 0 PPM
Copper 0 PPM 0 PPM
Silver 2.85 PPM 2.94 PPM
Nickel 0 PPM 0 PPM
Tin 0.59 PPM 0 PPM
Aluminum 1.79 PPM 0.71 PPM
Silicon 10.27 PPM 7.55 PPM
Iron 140.61 PPM 2.89 PPM
Glycol NEG N/A
Water NEG N/A
Fuel <5% N/A
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.