Features: 8' Wide Screed, Extends to 12' 7", Propane Heated Screed.
Meter Reading: 498 Hours
Serial Number:
Location: Louisiana, United States
Zip/Postal Code:70760
(Pointe Coupee County)
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Blemishes where decals have been removed; Scratches
Sheet Metal (Fiberglass) Condition Minor dents/scratches; Surface rust; Missing panels
Steps/Ladders No visible damage
Hand Rails No visible damage
General Appearance #1
 
Control Station
Horn Operational
Hydraulic Controls
Steering Control
Drivetrain Controls
Oil Pressure No oil pressure indicator
Warning Lights Inoperable
Gauges Operational
Hour Meter 498 Hours - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Limited Function Check (cs) The main components are in place and operational.
Hour Meter
 
Engine
Emission Control Label None found
Blow by @ idle (subjective observation) Minimal
Starter Operational
Fuel System Operational
Exhaust System No visible damage
Radiator Fin damage
Oil Leaks There is fluid accumulation on the side of the engine.
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check (Engine) The engine started and ran.See oil report.
Blow by @ idle (subjective observation)
 
Drivetrain
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Transmission Operational; Low oil level
Drive Motors Fluid Accumulation
Final Drives
Limited Function Check The drivetrain was operational.
Drivetrain #1
 
Hydraulics
Pumps (Hydraulics)
Valves
Hydraulic Tank Low oil level
Hoses (Hydraulics) There is braid exposure on the screed attachment hoses.
Screed Lift Cylinders Minor to moderate pin and bushing movement
Screed Extension Cylinders Fluid accumulation on the left cylinder; Fluid accumulation on the right cylinder; Minor to moderate pin and bushing movement
Limited Function Check The hydraulic system was operational without a load.
Hydraulics #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Screed Lift Arms Noticeable movement at pins
Screed Bottom Plate / Mat Material residue
Metering Gates
Auger/ Screw Condition Bearing damage
Hopper Wings
Screed Heaters Not operationally checked; LP tank not included
Screed Crown Adjustment Manual adjustment
Screed Angle of Attack Adjustment Manual adjustment
Screed Wear Plates Areas of wear through
Extension Tubes
End Gates
Spray Down System Not operationally checked
Limited Function Check There is fluid accumulation on the left auger drive motor box. The main chassis components functioned with minor to moderate wear in the pivot points.
Chassis #1
 
Undercarriage
Undercarriage components photos (links, bushings, sprockets, idlers, rollers, grousers) are selected as representative. Bidders are encouraged to review photos using the zoom feature to judge condition in detail.
Track Tensioners See photos for condition
Shoe Width 12" track shoes
Track link wear See photos for condition
Pins and Bushings Turned? No
Pins and bushing wear See photos for condition
Idlers See photos for condition
Pins and bushing wear
Oil Sample Analysis Engine
date of analysis Jul 03, 2012
Silicon 7 PPM
Lead 1 PPM
Tin 0 PPM
Copper 2 PPM
Aluminum 1 PPM
Silver 0.1 PPM
Nickel 0.2 PPM
Chromium 0.3 PPM
Iron 8 PPM
Glycol NEG
Water NEG
Fuel >5%

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2013 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet℠, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.