Home Page / 2012 Sullivan-Palatek DF375PDJD 375 CFM Air Compressor
 
Previous Next
Sold on
12/1/16
Winning Bid
US $6,500
# of Bids
8
SOLD!
ITEM DETAILS
Not Available
375 CFM, John Deere 4045 Engine, Ball Hitch, S/A

IronClad Assurance

Inspected by IronPlanet.

Your purchase is protected by our IronClad Assurance.

Inspection Report



Please note that as the buyer, you are responsible for reviewing the entire inspection report when evaluating an item.


General Appearance
Description Rating Details  
Federal Motor Vehicle Standards Compliance Label No
CE Mark (on or near data plate) No
Paint Click here to open photos and videos of this item.  
Sheet Metal (fiberglass) Condition Click here to open photos and videos of this item.  
Cowling, Insulation and Belly Pans Click here to open photos and videos of this item.  
(4)


Control Station
Description Rating Details  
Gauges Operational Click here to open photos and videos of this item.  
Oil Pressure The gauge registers in the operating range. Click here to open photos and videos of this item.  
Warning Lights Click here to open photos and videos of this item.  
Hour Meter (pre-inspection) 1,833.2 & 2,357.4 Hours; Two hour meters Click here to open photos and videos of this item.  
Hour Meter 1,833.6 & 2,357.5 Hours; Two hour meters - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed. Click here to open photos and videos of this item.  
Limited Function Check The main components are in place and operational. Click here to open photos and videos of this item.  
(8)


Engine
Description Rating Details  
Fuel Type Diesel
Emission Certification Label US EPA certification label Click here to open photos and videos of this item.  
Blow by @ idle (subjective observation) No noticeable vapor or pressure Click here to open photos and videos of this item.  
Starter Operational
Fuel System Click here to open photos and videos of this item.  
Exhaust System Click here to open photos and videos of this item.  
Radiator Click here to open photos and videos of this item.  
Oil Leaks None seen Click here to open photos and videos of this item.  
Fuel Leaks None seen Click here to open photos and videos of this item.  
Cooling System Leaks None seen Click here to open photos and videos of this item.  
Engine - Left Side Click here to open photos and videos of this item.  
Engine - Right Side Click here to open photos and videos of this item.  
Limited Function Check (Engine) After jump starting, the engine ran. The engine would not re-start after shutting down without jump starting.
(14)


Air Compressor
Description Rating Details  
Compressor Click here to open photos and videos of this item.  
Oil Separator Click here to open photos and videos of this item.  
Valves, Hoses and Piping Significant leak under unit Click here to open photos and videos of this item.  
Limited Function Check - Air Compressor The compressor builds air pressure; The related components leak air.
(5)


Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Description Rating Details  
Axle Condition Click here to open photos and videos of this item.  
Tire Size 205/75-15 Click here to open photos and videos of this item.  
Tire Condition Click here to open photos and videos of this item.  
Wheel Condition
Wheel Studs
Springs/Hangers Condition Click here to open photos and videos of this item.  
Tongue/ Hitch Condition Click here to open photos and videos of this item.  
Lights/Wiring Condition Functional Click here to open photos and videos of this item.  
Brake Lights Functional Yes Click here to open photos and videos of this item.  
Frame Rails/ Main Beams Condition Click here to open photos and videos of this item.  
Landing Gear / Tongue Jack Click here to open photos and videos of this item.  
Fuel Tank Condition Click here to open photos and videos of this item.  
(12)
 

Oil Sample Analysis
  engine
date of analysis Nov 21, 2016
Lead 4.11 PPM
Chromium 0 PPM
Copper 0.01 PPM
Silver 2.03 PPM
Nickel 0 PPM
Tin 0 PPM
Aluminum 2.52 PPM
Silicon 8.26 PPM
Iron 48.25 PPM
Glycol NEG
Water NEG
Fuel <5%
Disputes:
This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment's major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.