Back to Search Results / 2007 Sullair 1150XHH/1350HHADLOF 1350 CFM Air Compressor
 

2007 Sullair 1150XHH/1350HHADLOF 1350 CFM Air Compressor (#394640)

Search for other Air Compressors items

Winning Bid: US $33,000  
# of Bids: 33   View Bid History
Sold on: : 9/6/12
Auction Type: Featured Auction
SOLD!
Features: 1350 CFM, Caterpillar C18 Engine, Skid Mounted
Meter Reading: 6,805 Hours
Serial Number:
Location: Kentucky, United States
Zip/Postal Code:41653
(Floyd County)
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Restriction: Bidders from Canada:   Before bidding, please check with your Registrar of Imported Vehicles (RIV) regarding admissibility of this vehicle into Canada. Why?
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Scratches; Chips
Sheet Metal (fiberglass) Condition Scrapes; Surface rust in areas; See photos for condition
General Appearance #1
 
Control Station
Gauges Operational
Oil Pressure The fault indicator shuts off after the engine oil pressure rises.
Engine Warning Lights Operational
Hour Meter 6,805 Hours - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Limited Function Check The main components are in place and operational.
Hour Meter
 
Engine
Make and Model Caterpillar; C18 engine; 6 Cylinder Engine
Fuel Type Diesel
Emission Control Label None found
Blow by @ idle (subjective observation) Minor
Starter Operational
Turbo or Blower Operational
Fuel System Operational
Exhaust System No visible damage
Radiator Coolant had to be added; There is a hole in the radiator.
Oil Leaks There is fluid accumulation on the oil pan and the engine.
Fuel Leaks None seen
Cooling System Leaks There is a dripping leak at the radiator.
Limited Function Check The engine started and ran. A temporary fuel source was used to start the engine. See oil report.
Blow by @ idle (subjective observation)
 
Air Compressor
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Compressor Some oil residue
Oil Separator Oil residue
Valves, Hoses and Piping Chafed / weathered hoses
Limited Function Check - Air Compressor The compressor builds air pressure.
Air Compressor #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Frame Rails/ Main Beams Condition
Fuel Tank Condition There is NO fuel tank with this item.
Chassis #1
Oil Sample Analysis Engine
date of analysis Jul 13, 2012
Silicon 7 PPM
Lead 3 PPM
Tin 1 PPM
Copper 16 PPM
Aluminum 5 PPM
Silver 0.2 PPM
Nickel 1.2 PPM
Chromium 3.2 PPM
Iron 78 PPM
Glycol NEG
Water NEG
Fuel <5%

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2013 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet℠, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.