Back to Search Results / 2006 Sullivan D185Q11JDSB 185 CFM Air Compressor
 

2006 Sullivan D185Q11JDSB 185 CFM Air Compressor (#404359)

Search for other Air Compressors items

Winning Bid: US $5,400  
# of Bids: 20   View Bid History
Sold on: : 8/9/12
Auction Type: Featured Auction
SOLD!
Features: 185 CFM, 100 PSIG, John Deere 4024TF270C Engine, Single Axle Trailer Chassis, Ball Hitch
Meter Reading: 1,502 Hours
Serial Number:
Location: Louisiana, United States
Zip/Postal Code:70072
(New Orleans area)
Shipping: See shipping details for important pickup requirements and to get a shipping estimate
Inspection Report : Protected by IronClad Assurancenotes
Payment: Payment due within 3 business days after auction. See Details
Restriction: Bidders from Canada:   Before bidding, please check with your Registrar of Imported Vehicles (RIV) regarding admissibility of this vehicle into Canada. Why?
Inspection Report Payment Shipping Financing  
Inspection Ratings Key
Limited use or recently replaced, free of visible wear or defects
Performs within the tolerances expected for age and type of item
Although performing, shows indication of needing repair or replacement
Needs immediate repair/replacement. Requires work if it is to perform
as expected
 
General Appearance
CE Mark (on or near data plate) No
Paint Not original paint; Scratches; Chips; See photos for condition
Sheet Metal (fiberglass) Condition Bent panels
Cowling, Insulation and Belly Pans
General Appearance #1
 
Control Station
Gauges Operational
Oil Pressure The gauge registers in the operating range.
Warning Lights Operational
Hour Meter 1,502 Hours; Operational hour meter - IronPlanet makes no guarantees as to actual hours/miles; we can only report what can be visually observed.
Limited Function Check (cs) The main components are in place and operational.
Hour Meter
 
Engine
Make and Model John Deere 4024TF270C engine; Serial #: PE4024T108592; 4 Cylinder Engine
Fuel Type Diesel
Emission Control Label US EPA certification label
Blow by @ idle (subjective observation) Minimal
Starter Operational
Turbo or Blower Operational
Fuel System Operational
Exhaust System No visible damage
Radiator
Oil Leaks There is fluid accumulation on the side of engine.
Fuel Leaks None seen
Cooling System Leaks None seen
Limited Function Check (Engine) The engine started and ran. See oil report.
Emission Control Label
 
Air Compressor
Operational test is limited to low speed in a confined flat area without load. Differential interlocks, full transmission shifting and functionality of all drive axles cannot be fully verified. Inspector listens for abnormal noises, observes leaks and notes physical damage.
Compressor
Oil Separator
Valves, Hoses and Piping
Limited Function Check - Air Compressor The compressor builds air pressure.
Air Compressor #1
 
Chassis
IronPlanet pin connection pivot point wear inspections are limited to sound, sight and feel observations. Dial indicator testing is not performed.
Axle Condition
Tire Size 205/75D15 Tires; Brand(s): Carlisle
Tire Condition Minor cuts and gouges
Wheel Condition
Wheel Studs
Springs/Hangers Condition
Tongue/ Hitch Condition
Lights/Wiring Condition Not operationally checked
Marker Lights Functional Not operationally checked
Brake Lights Functional Not operationally checked
License Plate Light Functional Not operationally checked
Frame Rails/ Main Beams Condition
Landing Gear / Tongue Jack
Fuel Tank Condition
Chassis #1
Oil Sample Analysis Engine
date of analysis Jul 27, 2012
Silicon 21 PPM
Lead 1 PPM
Tin 0 PPM
Copper 1 PPM
Aluminum 2 PPM
Silver 0.2 PPM
Nickel 1.5 PPM
Chromium 0.6 PPM
Iron 22 PPM
Glycol NEG
Water NEG
Fuel <5%

Disputes: This item is offered with IronClad Assurance® protection. With IronClad Assurance®, if a buyer discovers that the item is not substantially in the condition as represented in this inspection report, the buyer may submit a written dispute claim to IronPlanet. Following submission of a written dispute claim, IronPlanet will investigate the claim, re-inspecting the equipment item as necessary, and determine a fair and mutually beneficial resolution. Please note that IronPlanet inspections are performed solely for the purpose of reporting the visible condition of the equipment''s major systems and attachments on the day of the inspection and do not include load testing or digging/lifting. These inspections are not designed nor intended to detect latent defects, or conditions that could only be found in connection with the physical dismantling of the equipment or the use of diagnostic tools or techniques. This inspection report includes ratings, comments, and photos of the various components of the item. Knowledgeable buyers are expected to carefully review all of the available information in the inspection report, including all photographs, in order to make the best bidding and buying decision possible.
Warranty by Premium 2000

Place holder (To be provided by P2000)

TO DO: Window size adjustments based on actual data

Engine Coverage.  some text.

Transmission Coverage.  blah blah.

Affordable plans.

Learn more!
Copyright © 1999-2013 IronPlanet, Inc. All Rights Reserved. IronPlanet®, TruckPlanet℠, IronClad Assurance® and Auctions you can trust® are service marks of IronPlanet, Inc. All other marks and brands are the property of their respective owners.